W DOC AIRBUS | AMM A320F

Inspection/Check of the Ignition Exciter [CFMI]


TASK 74-11-10-200-001-A
Inspection/Check of the Ignition Exciter


WARNING: BEFORE YOU START WORK ON THE IGNITION SYSTEM, MAKE SURE THAT THE IGNITION EXCITERS ARE DE-ENERGIZED FOR A MINIMUM OF FIVE MINUTES. ALSO DO NOT TOUCH THE ELECTRICAL CONTACTS. THE IGNITION SYSTEM VOLTAGE IS VERY HIGH, AND THE IGNITION EXCITERS CAN HAVE AN ELECTRICAL CHARGE EVEN WHEN NOT ENERGIZED. IF YOU DO NOT OBEY THESE PRECAUTIONS, INJURY CAN OCCUR.
FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
FIN: 4000JH1 ** ON A/C NOT FOR ALL
FIN: 4000JH2 ** ON A/C NOT FOR ALL
1. Reason for the Job
The upper ignition exciter is connected to the right ignition lead. The lower ignition exciter is for the left ignition lead.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-040-A
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-A
Closing of the Fan Cowl Doors
TASK 74-11-10-000-001-A
Removal of the Ignition Exciter
TASK 74-11-10-100-001-A
Cleaning of the Ignition Exciter
TASK 74-11-10-400-001-A
Installation of the Ignition Exciter
3. Job Set-up
Subtask 74-11-10-941-051-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 74-11-10-865-050-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUENGINE/1 AND 2/IGN/SYS A1JHA03
FOR FIN: 1000EM1 (ENGINE1)
121VUENGINE/IGN/ENG1/SYS B3JH1P41
121VUENGINE/IGN/ENG1/SYS A BAT2JH1P39
FOR FIN: 1000EM2 (ENGINE2)
121VUENGINE/IGN/ENG2/SYS B3JH2P42
121VUENGINE/IGN/ENG2/SYS A BAT2JH2P40
Subtask 74-11-10-010-050-A ** ON A/C NOT FOR ALL
C. Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
   (1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (a) FOR [1000EM2] (ENGINE-2)
447AL 448AR
4. Procedure
Subtask 74-11-10-210-050-A ** ON A/C NOT FOR ALL
A. Do a Visual Inspection of the Ignition Exciter.
INSPECT/CHECK
MAXIMUM SERVICEABLE LIMITS
REMARKS
1.All areas for :


  • Cracks
Not serviceable.
Replace exciter (Ref. AMM TASK 74-11-10-000-001) and (Ref. AMM TASK 74-11-10-400-001).
  • Nicks, dents and scratches.
Any number 0.030 in. (0.76 mm) deep.
Replace exciter (Ref. AMM TASK 74-11-10-000-001) and (Ref. AMM TASK 74-11-10-400-001).
2.Electrical connectors for :


  • Thread damage.
30 percent damage on one lead-in or 20 percent damage of 2 lead-in threads.
Replace exciter (Ref. AMM TASK 74-11-10-000-001) and (Ref. AMM TASK 74-11-10-400-001).
  • Pin damage.
Must mate freely with respective leads.
Replace exciter if pins are broken, eroded or seized (Ref. AMM TASK 74-11-10-000-001) and (Ref. AMM TASK 74-11-10-400-001)
  • Dirt inside connector well.
Not serviceable.
Clean connector well (Ref. AMM TASK 74-11-10-100-001).
5. Close-up
Subtask 74-11-10-865-051-A ** ON A/C NOT FOR ALL
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUENGINE/1 AND 2/IGN/SYS A1JHA03
FOR FIN: 1000EM1 (ENGINE1)
121VUENGINE/IGN/ENG1/SYS B3JH1P41
121VUENGINE/IGN/ENG1/SYS A BAT2JH1P39
FOR FIN: 1000EM2 (ENGINE2)
121VUENGINE/IGN/ENG2/SYS B3JH2P42
121VUENGINE/IGN/ENG2/SYS A BAT2JH2P40
Subtask 74-11-10-410-050-A ** ON A/C NOT FOR ALL
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the fan cowl doors: (Ref. AMM TASK 71-13-00-410-040)
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (3) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 03:06:53 UTC