W DOC AIRBUS | AMM A320F

Removal of the HJ6B Engine Wiring Harness [CFML]


TASK 73-21-60-000-811-A
Removal of the HJ6B Engine Wiring Harness


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
FIN: 4144KS
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
CAP - PROTECTION
No specific
AR
COVER - PROTECTION
No specific
1
PLIERS - JAWED, SOFT
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL, 438AR
FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL, 448AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-803-A
Opening of the Fan Cowl Doors
3. Job Set-up
Subtask 73-21-60-941-073-A
A. Safety Precautions
   (1) On the center pedestal, on ENG panel 115VU:
     (a) Make sure that the ENG/MODE selector switch is in the NORM position.
     (b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
     (c) Put WARNING NOTICE(S) in position to tell persons not to operate:
  • The ENG/MODE selector switch
  • The ENG/MASTER 1(2) control switch.
   (2) On the ENG section of maintenance panel 50VU:
     (a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 73-21-60-010-076-A
B. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
   (2) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
4. Procedure
Subtask 73-21-60-020-062-A
A. Removal of the HJ6B Engine Wiring Harness (4144KS)
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
CAUTION: USE PLIERS THAT HAVE TEFLON JAWS TO TIGHTEN OR LOOSEN THE ELECTRICAL CONNECTORS. DO NOT USE PLIERS THAT HAVE METAL JAWS. METAL JAWS CAN CAUSE DAMAGE TO THE ELECTRICAL CONNECTORS.
   (1) Disconnection of the HJ6B engine wiring harness (4144KS) (1):
NOTE: If necessary , use PLIERS - JAWED, SOFT to disconnect the electrical connectors.
     (a) Disconnect the HJ6B engine wiring harness (1) connector from the EEC channel B J6 receptacle (4601KS2) (3) (at the 3 o'clock position).
     (b) Disconnect the HJ6B engine wiring harness (1) connector from the HJ6A engine wiring harness receptacle (4143KS) (7) (at the 4 o'clock position).
     (c) Disconnect the HJ6B engine wiring harness (1) connector from the PSS channel B receptacle (4700KS) (9) (at the 4:30 o'clock position).
     (d) Disconnect the HJ6B engine wiring harness (1) connector from the Oil Debris Monitoring (ODM) unit channel B receptacle (4074KS) (8) (at the 3 o'clock position).
     (e) Disconnect the HJ6B engine wiring harness (1) connector from the T12 sensor channel B receptacle (4001KS) (17) (at the 12 o'clock position).
     (f) Disconnect the HJ6B engine wiring harness (1) connector from the N2 sensor channel B receptacle (4065KS) (27) (at the 9 o'clock position).
     (g) Disconnect the HJ6B engine wiring harness (1) connector from the oil pressure and temperature sensor channel B receptacle (4079KS) (28) (at the 10 o'clock position).
   (2) Removal of the nuts and bolts from the clamps that attach to the HJ6B engine wiring harness (1):
     (a) Remove the nut (5) and bolt (6) from the clamp (4).
     (b) Remove the nut (15) and bolt (14) from the clamp (16).
     (c) Remove the nut (18) and bolt (19) from the clamp (20).
   (3) Removal of the bolts from the clamps that attach to the HJ6B engine wiring harness (1):
     (a) Remove the bolt (13) from the clamp (10).
     (b) Remove the bolt (11) from the clamp (12).
     (c) Remove the bolt (22) from the clamp (21).
     (d) Remove the bolt (24) from the clamp (25).
     (e) Remove the bolt (26) from the clamp (23).
   (4) Remove the HJ6B engine wiring harness (1) from the 21 clips (2) along its routing.
   (5) Carefully remove the HJ6B engine wiring harness (1) from the engine.
   (6) Install the COVER - PROTECTION and the CAP - PROTECTION on all the open ports, open tubes, open hoses and disconnected connectors.
[Rev.10 from 2021] 2026.04.01 03:05:25 UTC