Leak Check and Functional Test of the Fuel Return Valve [CFMB]
TASK 73-11-50-360-002-A
Leak Check and Functional Test of the Fuel Return Valve
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 73-11-50-941-057-A ** ON A/C NOT FOR ALL
Subtask 73-11-50-360-055-A ** ON A/C NOT FOR ALL
Subtask 73-11-50-410-057-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 02:58:09 UTC
Leak Check and Functional Test of the Fuel Return Valve
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | PLIERS - NOSE, SOFT, LONG |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-00-00-710-006-B | Minimum Idle Check |
| TASK 71-00-00-710-028-B | Engine Shutdown |
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-B | Closing of the Fan Cowl Doors |
| TASK 73-29-00-710-040-B-02 | Operational Test of the FADEC on the Ground (with Engine Non motoring) |
Subtask 73-11-50-941-057-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 73-11-50-010-058-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
B. Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
(1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
Subtask 73-11-50-360-055-A ** ON A/C NOT FOR ALL
A. Leak check of the fuel return valve
(1) Disconnect the electrical connector C132 of HJ13 harness from the oil temperature sensor.
(2) Do a minimum idle check (Ref. AMM TASK 71-00-00-710-006).
(a) Ignore FADEC 1(2) maintenance status.
(b) Make specially sure there is no leaks at the FRV tubing connections while the engine operates.
(c) Make sure that on the EWD, the warning below does not come into view while the engine operates :
ENG 1, (2) : FUEL RETURN VALVE, VALVE NOT OPEN
(3) Stop the engine (Ref. AMM TASK 71-00-00-710-028).
(a) Make sure that the FADEC 1(2) maintenance status is associated to the CFDS message EOT SNSR, J13, ECU.
(b) Make sure that on the EWD, the warning below does not come into view during engine shut down :
Subtask 73-11-50-710-050-A ** ON A/C NOT FOR ALL 5. Close-up(1) Disconnect the electrical connector C132 of HJ13 harness from the oil temperature sensor.
(2) Do a minimum idle check (Ref. AMM TASK 71-00-00-710-006).
(a) Ignore FADEC 1(2) maintenance status.
(b) Make specially sure there is no leaks at the FRV tubing connections while the engine operates.
(c) Make sure that on the EWD, the warning below does not come into view while the engine operates :
ENG 1, (2) : FUEL RETURN VALVE, VALVE NOT OPEN
(3) Stop the engine (Ref. AMM TASK 71-00-00-710-028).
(a) Make sure that the FADEC 1(2) maintenance status is associated to the CFDS message EOT SNSR, J13, ECU.
(b) Make sure that on the EWD, the warning below does not come into view during engine shut down :
- ENG 1, (2) : FUEL RETURN VALVE, VALVE NOT CLOSED
Subtask 73-11-50-410-057-A ** ON A/C NOT FOR ALL
Electrical Harness HJ13