Removal of the Fuel Return Valve Hose [CFMI]
TASK 73-11-48-000-040-A
Removal of the Fuel Return Valve Hose
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 73-11-48-941-053-A ** ON A/C NOT FOR ALL
Subtask 73-11-48-020-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 13:04:48 UTC
Removal of the Fuel Return Valve Hose
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| No specific | 1 | CONTAINER 20 L - SHALLOW |
| No specific | AR | COVER - PROTECTION |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-040-A | Opening of the Fan Cowl Doors |
Subtask 73-11-48-941-053-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 73-11-48-010-053-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
B. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 1M(3 FT) in position.
4. Procedure(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 1M(3 FT) in position.
Subtask 73-11-48-020-051-A ** ON A/C NOT FOR ALL
A. Removal of the Fuel/Return Bypass Valve Hose
(1) Put a CONTAINER 20 L - SHALLOW near the fuel/return bypass valve (15) to catch the drained fuel.
(2) Disconnect the hose (5) from the fuel/return bypass valve (15). Let the fuel drain into the container.
(3) Cut and remove the lockwire from the bolts (35).
(4) Remove the bolts (35) and the washers (40), that attach the hose (5) to the fluid disconnect panel.
(5) Remove and Discard the gasket (30).
(6) Remove the screw (20), washer (25) and clamp (10) that attach the fuel/return bypass valve hose (5) to the bracket at flange Sta. 176.
(7) Remove the screws (20), washers (25) and clamps (10) that attach the fuel/return bypass valve hose (5) to the brackets at flange Sta. 170. (Two location).
(8) Remove the clamps (10) from the hose (5).
(9) Put COVER - PROTECTION on the two ends of the hose (5), the fluid disconnect panel, and the fuel/return bypass valve.
(1) Put a CONTAINER 20 L - SHALLOW near the fuel/return bypass valve (15) to catch the drained fuel.
(2) Disconnect the hose (5) from the fuel/return bypass valve (15). Let the fuel drain into the container.
(3) Cut and remove the lockwire from the bolts (35).
(4) Remove the bolts (35) and the washers (40), that attach the hose (5) to the fluid disconnect panel.
(5) Remove and Discard the gasket (30).
(6) Remove the screw (20), washer (25) and clamp (10) that attach the fuel/return bypass valve hose (5) to the bracket at flange Sta. 176.
(7) Remove the screws (20), washers (25) and clamps (10) that attach the fuel/return bypass valve hose (5) to the brackets at flange Sta. 170. (Two location).
(8) Remove the clamps (10) from the hose (5).
(9) Put COVER - PROTECTION on the two ends of the hose (5), the fluid disconnect panel, and the fuel/return bypass valve.
Fuel/Return Bypass Valve Hose