W DOC AIRBUS | AMM A320F

Replacement of The Fan Case Lease Plate Bracket [PW11]


TASK 72-21-01-960-801-A
Replacement of The Fan Case Lease Plate Bracket


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
ZONE: 400
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE
No specific
Torque wrench: range to between 30 and 26 lbf.in (0.34 and 0.29 m.daN ) T
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
400
POWER PLANT, NACELLES AND PYLONS
FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL, 438AR
FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL, 448AR
 C. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
1
BRACKET
EIPC 72-21-01-04-100
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 71-00-00-860-833-A
Procedure to Prevent Engine Motoring
TASK 71-13-00-010-802-A
Opening of the Fan Cowl Doors
TASK 71-13-00-410-802-A
Closing of the Fan Cowl Doors
3. Job Set-up
Subtask 72-21-01-941-061-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833)
Subtask 72-21-01-010-059-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL, 438AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL, 448AR.
   (2) Put the ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in position.
4. Procedure
Subtask 72-21-01-960-051-A ** ON A/C NOT FOR ALL
A. Replacement of the Fan Case Lease Plate Bracket
CAUTION: WIPE CLEAN ALL PARTS AND TOOLS AS NECESSARY TO REMOVE UNWANTED DEBRIS AND PREVENT DAMAGE TO THE ENGINE.
   (1) Remove the four nuts (2) and bracket (1) from the fan case.
   (2) Install the new EIPC 72-21-01-04-100 BRACKET (1) to the fan case with the four nuts (2).
   (3) TORQUE the four nuts (2) to between 30 and 26 lbf.in (0.34 and 0.29 m.daN )
T.
   (4) Examine the assembly for foreign objects, damage, and correct assembly.
5. Close-up
Subtask 72-21-01-410-056-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the fan cowl doors (
Ref. AMM TASK 71-13-00-410-802):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL, 438AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL, 448AR.
   (3) Remove the access platform(s).
   (4) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 13:02:34 UTC