Preservation Procedure for Exceeded Long Term Preservation Period [CFML]
TASK 72-00-00-620-806-A
Preservation Procedure for Exceeded Long Term Preservation Period
Self explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 72-00-00-860-120-A
Subtask 72-00-00-620-076-A
[Rev.10 from 2021]
2026.04.01 02:50:35 UTC
Preservation Procedure for Exceeded Long Term Preservation Period
ZONE: 400
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 400 | POWER PLANT, NACELLES AND PYLONS |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 72-00-00-620-807-A | Preservation Renewal Requirements |
Subtask 72-00-00-860-120-A
A. Not Applicable
4. ProcedureSubtask 72-00-00-620-076-A
A. Preservation Procedure for Exceeded Long Term Preservation Period
(1) If the engine preservation period is expired, refer to your CFMI representative for instruction.
(1) If the engine preservation period is expired, refer to your CFMI representative for instruction.
NOTE: An engineering analysis must be used to analyze the situation applicable to each special case. As a minimum, the following parameters are to be provided:
(1) LEAP engine model and engine serial number.
(2) Engine TSN and CSN.
(3) Date of last preservation task performed and reference of the task.
(5) Total period of improper preservation.
(8) Engine storage locations and conditions with the information that follows:
(10) In particular case of an engine which had an IFSD, confirmation that dry-out and re-lubrication were performed within 24 hours after IFSD.
(11) Is the engine going to shop visit?
(1) LEAP engine model and engine serial number.
(2) Engine TSN and CSN.
(3) Date of last preservation task performed and reference of the task.
- In case of multiple renewal procedure performed, provide complete history and dates.
(5) Total period of improper preservation.
- Detail if maximum extended period allowed in preservation renewal for engine that has expired preservation (Ref. AMM TASK 72-00-00-620-807) has been reached.
- Oil system preserved
- Fuel system preserved
- Variable bleed valves were closed and/or sealed with a vapor barrier film or alternative grid protection
- All open tubes, hoses and electrical connections were capped and plugged
- Desiccant bags and humidity indicators were installed and monitoring history
- Engine inlet and exhausts were sealed with vapor barrier film
- Engine covers were installed (whole engine or inlet and exhaust only).
(8) Engine storage locations and conditions with the information that follows:
- Inside storage or outside storage
- Temperature variation and humidity level encountered during out of operation period
- Confirm exposure to windmilling, if engine stored outside without cover.
(10) In particular case of an engine which had an IFSD, confirmation that dry-out and re-lubrication were performed within 24 hours after IFSD.
(11) Is the engine going to shop visit?