Installation of the High Speed Tape (Nacelle Anti-Icing (NAI) Hoisting Point Plug) [PW11]
TASK 71-61-00-040-805-A
Installation of the High Speed Tape (Nacelle Anti-Icing (NAI) Hoisting Point Plug)
CDL 71-06
NAI Hoisting Point Plug
To remove the inlet cowl hoist point insert bolt(s) and install high speed tape after the insert bolt(s) has become damaged or missing.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 71-61-00-941-084-A ** ON A/C NOT FOR ALL
Subtask 71-61-00-420-062-A ** ON A/C NOT FOR ALL
Subtask 71-61-00-410-061-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 02:33:24 UTC
Installation of the High Speed Tape (Nacelle Anti-Icing (NAI) Hoisting Point Plug)
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING:
WEAR APPLICABLE PERSONAL PROTECTIVE EQUIPMENT (PPE) WHEN YOU DO THIS TASK. BEFORE YOU USE PPE, READ, UNDERSTAND AND OBEY ALL INSTRUCTIONS FOR ITS USE. THESE INSTRUCTIONS INCLUDE INSTRUCTIONS FROM THE MANUFACTURER, YOUR EMPLOYER AND GOVERNMENT REGULATIONS. YOU CAN GET INJURED IF YOU DO NOT USE PPE. GET INSTRUCTIONS FROM YOUR EMPLOYER ON WHICH PPE IS NECESSARY.
1. Reason for the JobCDL 71-06
NAI Hoisting Point Plug
To remove the inlet cowl hoist point insert bolt(s) and install high speed tape after the insert bolt(s) has become damaged or missing.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.05RAB9) | Adhesive Film Tape-- Aluminium Foil - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1) | |
| 437AL, 438AR | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-00-00-860-833-A | Procedure to Prevent Engine Motoring |
| TASK 71-13-00-010-802-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-802-A | Closing of the Fan Cowl Doors |
| SRM 517712 | |
Subtask 71-61-00-941-084-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
Subtask 71-61-00-010-060-A ** ON A/C NOT FOR ALL (1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
B. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
(2) Put an ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in position.
4. Procedure(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
(2) Put an ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in position.
Subtask 71-61-00-420-062-A ** ON A/C NOT FOR ALL
A. Installation of the High Speed Tape
(2) Cut the Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) to the correct dimensions to the opening of the inlet cowl hoist point(s) SRM 517712.
(3) Apply the Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) to the opening of the inlet cowl hoist point(s) SRM 517712.
(4) Make the Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) smooth on the mating surfaces of the inlet cowl. Remove the air pockets and push the edges of the Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) tightly SRM 517712.
(5) Make sure that the Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) gives the same protection as the insert bolt(s).
5. Close-upWARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
(1) If the damaged insert bolt(s) are there, remove the bolt(s) from the hoist point(s) on the inlet cowl. (2) Cut the Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) to the correct dimensions to the opening of the inlet cowl hoist point(s) SRM 517712.
(3) Apply the Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) to the opening of the inlet cowl hoist point(s) SRM 517712.
(4) Make the Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) smooth on the mating surfaces of the inlet cowl. Remove the air pockets and push the edges of the Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) tightly SRM 517712.
(5) Make sure that the Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) gives the same protection as the insert bolt(s).
Subtask 71-61-00-410-061-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
Inlet Cowl Hoist Point Plug