Installation of the Pylon Fan Cowl Latch Proximity Sensor Harness [PW11]
TASK 71-13-61-400-802-A
Installation of the Pylon Fan Cowl Latch Proximity Sensor Harness
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 71-13-61-941-053-A ** ON A/C NOT FOR ALL
Subtask 71-13-61-420-051-A ** ON A/C NOT FOR ALL
Subtask 71-13-61-410-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 02:32:54 UTC
Installation of the Pylon Fan Cowl Latch Proximity Sensor Harness
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
FIN: 4145KS ** ON A/C NOT FOR ALL
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | 1 | PLIERS - JAWED, SOFT |
| No specific | Torque wrench: range to between 35 and 31.5 lbf.in (0.40 and 0.36 m.daN ) ![]() |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1) | |
| 437AL, 438AR | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-00-00-860-833-A | Procedure to Prevent Engine Motoring |
| TASK 71-13-00-010-802-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-802-A | Closing of the Fan Cowl Doors |
| TASK 71-13-00-710-802-A | Operational test of the Fan Cowl Loss Prevention System |
Subtask 71-13-61-941-053-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Make sure that you did the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
Subtask 71-13-61-865-054-A ** ON A/C NOT FOR ALL (1) Make sure that you did the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
Subtask 71-13-61-010-053-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/LATCH DOORS & SLATS/ENG2 | 93KS2 | P40 |
| 121VU | ENGINE/LATCH DOORS & SLATS/ENG1 | 93KS1 | P39 |
C. Get Access
(1) Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL, 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL, 448AR
(2) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position.
4. Procedure(1) Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL, 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL, 448AR
(2) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position.
Subtask 71-13-61-420-051-A ** ON A/C NOT FOR ALL
A. Installation of the Fan Cowl Latch Proximity Sensor Harness
(1) Removal of the protection covers
(2) If necessary, install the clamp (2).
(a) Install the clamp (2) on the TRAS harness disconnect bracket with the two bolts (3) and the two washers (4).
(b) TORQUE the bolts (3) to between 35 and 31.5 lbf.in (0.40 and 0.36 m.daN )
.
(3) Install the pylon fan cowl latch proximity sensor harness (1) (4145KS).
(a) Connect the harness (1) (443VC-A) to the pylon interface.
(d) Put the fan cowl latch proximity sensor harness (1) in the clamp (2) and close the clamp (2).
(e) Turn the nut on the clamp (2) 1/4 of a turn to safety the nut.
(g) Turn the pylon fan cowl latch proximity sensor harness (1) connector (443VC-A) finger-tight. Turn the connector 1/4 turn more with PLIERS - JAWED, SOFT.
(h) Turn the pylon fan cowl latch proximity sensor harness (1) connector (4056VC-A) finger-tight. Turn the connector 1/4 turn more with PLIERS - JAWED, SOFT.
(i) Tighten the bolt on the clamp (2) until the spring is fully compressed against the clamp band. Make sure that there are no gaps between the spring and the clamp band.
5. Close-up(1) Removal of the protection covers
CAUTION:
REMOVE THE PROTECTION COVERS FROM THE OPENINGS AS NECESSARY TO PREVENT ENGINE DAMAGE.
(a) Make sure that you remove all the necessary COVER - PROTECTION to prevent damage to the engine. (2) If necessary, install the clamp (2).
(a) Install the clamp (2) on the TRAS harness disconnect bracket with the two bolts (3) and the two washers (4).
(b) TORQUE the bolts (3) to between 35 and 31.5 lbf.in (0.40 and 0.36 m.daN )
. (3) Install the pylon fan cowl latch proximity sensor harness (1) (4145KS).
(a) Connect the harness (1) (443VC-A) to the pylon interface.
NOTE: Do not tighten the connector at this time.
(b) Connect the harness (1) (4056VC-A) to the fan cowl proximity sensor harness. NOTE: Do not tighten the connector at this time.
(c) If the clamp (2) is closed, turn the nut on the clamp (2) 1/4 of a turn and open the clamp (2). (d) Put the fan cowl latch proximity sensor harness (1) in the clamp (2) and close the clamp (2).
(e) Turn the nut on the clamp (2) 1/4 of a turn to safety the nut.
NOTE: Do not tighten the bolt on the clamp (2) at this time.
(f) Adjust the fan cowl latch proximity sensor harness (1) to keep preload to a minimum. Make sure that there are no kinks. (g) Turn the pylon fan cowl latch proximity sensor harness (1) connector (443VC-A) finger-tight. Turn the connector 1/4 turn more with PLIERS - JAWED, SOFT.
(h) Turn the pylon fan cowl latch proximity sensor harness (1) connector (4056VC-A) finger-tight. Turn the connector 1/4 turn more with PLIERS - JAWED, SOFT.
(i) Tighten the bolt on the clamp (2) until the spring is fully compressed against the clamp band. Make sure that there are no gaps between the spring and the clamp band.
NOTE: Do not tighten the screw too much.
Subtask 71-13-61-410-051-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
Subtask 71-13-61-865-055-A ** ON A/C NOT FOR ALL (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 71-13-61-710-051-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/LATCH DOORS & SLATS/ENG2 | 93KS2 | P40 |
| 121VU | ENGINE/LATCH DOORS & SLATS/ENG1 | 93KS1 | P39 |
C. Test
(1) Do the operational test of the fan cowl loss prevention system proximity sensors (Ref. AMM TASK 71-13-00-710-802).
(1) Do the operational test of the fan cowl loss prevention system proximity sensors (Ref. AMM TASK 71-13-00-710-802).
Fan Cowl Latch Proximity Sensor Harness