Installation of the Fan Cowl Latch Proximity Sensor Harness [PW11]
TASK 71-13-61-400-801-A
Installation of the Fan Cowl Latch Proximity Sensor Harness
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 71-13-61-941-051-A ** ON A/C NOT FOR ALL
Subtask 71-13-61-410-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 12:57:26 UTC
Installation of the Fan Cowl Latch Proximity Sensor Harness
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING:
WEAR APPLICABLE PERSONAL PROTECTIVE EQUIPMENT (PPE) WHEN YOU DO THIS TASK. BEFORE YOU USE PPE, READ, UNDERSTAND AND OBEY ALL INSTRUCTIONS FOR ITS USE. THESE INSTRUCTIONS INCLUDE INSTRUCTIONS FROM THE MANUFACTURER, YOUR EMPLOYER AND GOVERNMENT REGULATIONS. YOU CAN GET INJURED IF YOU DO NOT USE PPE. GET INSTRUCTIONS FROM YOUR EMPLOYER ON WHICH PPE IS NECESSARY.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 400 | POWER PLANT, NACELLES AND PYLONS |
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1) | |
| 437AL, 438AR | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-00-00-860-833-A | Procedure to Prevent Engine Motoring |
| TASK 71-13-00-010-802-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-802-A | Closing of the Fan Cowl Doors |
| TASK 71-13-00-710-802-A | Operational test of the Fan Cowl Loss Prevention System |
Subtask 71-13-61-941-051-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Make sure that you did the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
Subtask 71-13-61-010-051-A ** ON A/C NOT FOR ALL (1) Make sure that you did the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
B. Get Access
(1) Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL, 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL, 448AR.
(2) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position.
Subtask 71-13-61-865-051-A ** ON A/C NOT FOR ALL (1) Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL, 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL, 448AR.
(2) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position.
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/LATCH DOORS & SLATS/ENG2 | 93KS2 | P40 |
| 121VU | ENGINE/LATCH DOORS & SLATS/ENG1 | 93KS1 | P39 |
CAUTION:
WIPE CLEAN ALL PARTS AND TOOLS AS NECESSARY TO REMOVE UNWANTED DEBRIS AND PREVENT DAMAGE TO THE ENGINE.
Subtask 71-13-61-420-050-A ** ON A/C NOT FOR ALL A. Installation of the Fan Cowl Latch Proximity Sensor Harness
(1) Removal of protection covers
CONFIGURATION 1
(2) Install the fan cowl latch proximity sensor harness (3).
(a) Attach the proximity sensor harness (3) connector (4056VC) to the disconnect bracket with the four screws (2) and four washers (1).
(b) Tighten the screws (2) by hand.
(c) Connect the proximity sensor harness (3) connectors (4233KS-A), (4232KS-A) and (4231KS-A) to the proximity sensors on the fan cowl latches.
(d) Turn the proximity sensor harness (3) connectors (4233KS-A), (4232KS-A) and (4231KS-A) finger-tight. Turn the connectors 1/4 turn more with PLIERS - JAWED, SOFT.
(e) Put the 16 clamps (4) and clamp (6) on the proximity sensor harness (3).
(f) Install the 16 clamps (4) and proximity sensor harness (3) on the fan cowl door with the 16 bolts (5).
1 Do not torque the bolts (5) at this time.
(g) Install the clamp (6) and the proximity sensor harness (3) on the fan cowl door with the bolt (5).
1 Do not torque the bolt (5) at this time.
(h) Adjust the proximity sensor harness (3) to keep preload to a minimum. Make sure there are no kinks in the proximity sensor harness (3).
(i) TORQUE the bolts (5) to between 35 and 31.5 lbf.in (0.40 and 0.36 m.daN )
.
(j) Connect the pylon harness connector (4056VC-A) to the proximity sensor harness (3) connector (4056VC).
(k) Turn the pylon harness connector (4056VC-A) finger-tight. Turn the connector 1/4 turn more with PLIERS - JAWED, SOFT.
CONFIGURATION 2
(3) Install the fan cowl latch proximity sensor harness (7).
(a) Attach the proximity sensor harness (7) connector (4056VC) to the disconnect bracket with the four screws (2) and four washers (1).
(b) Tighten the screws (2) by hand.
(c) Connect the proximity sensor harness (7) connectors (4233KS-A), (4232KS-A) and (4231KS-A) to the proximity sensors on the fan cowl latches.
(d) Turn the proximity sensor harness (7) connectors (4233KS-A), (4232KS-A) and (4231KS-A) finger-tight. Turn the connectors 1/4 turn more with PLIERS - JAWED, SOFT.
(e) Put the 14 clamps (8), two clamps (11) and clamp (12) on the proximity sensor harness (7).
(f) Install the 14 clamps (8) and proximity sensor harness (7) on the fan cowl door with the 14 washers (10) and 14 nuts (9).
1 Do not torque the nuts (9) at this time.
(g) Install the two clamps (11) and the proximity sensor harness (7) on the fan cowl door with the two washers (10) and two nuts (9).
1 Do not torque the nuts (9) at this time.
(h) Install the clamp (12) and the proximity sensor harness (7) on the fan cowl with the washer (10) and nut (9).
1 Do not torque the nut (9) at this time.
(i) Adjust the proximity sensor harness (7) to keep preload to a minimum. Make sure there are no kinks in the proximity sensor harness (7).
(j) TORQUE the nuts (9) to between 27 and 24 lbf.in (0.31 and 0.27 m.daN )
.
(k) Connect the pylon harness connector (4056VC-A) to the proximity sensor harness (7) connector (4056VC).
(l) Turn the pylon harness connector (4056VC-A) finger-tight. Turn the connector 1/4 turn more with PLIERS - JAWED, SOFT.
5. Close-up(1) Removal of protection covers
CAUTION:
REMOVE THE PROTECTION COVERS FROM THE OPENINGS AS NECESSARY TO PREVENT ENGINE DAMAGE.
(a) Make sure that you remove all the necessary COVER - PROTECTION to prevent damage to the engine. CONFIGURATION 1
(2) Install the fan cowl latch proximity sensor harness (3).
(a) Attach the proximity sensor harness (3) connector (4056VC) to the disconnect bracket with the four screws (2) and four washers (1).
(b) Tighten the screws (2) by hand.
(c) Connect the proximity sensor harness (3) connectors (4233KS-A), (4232KS-A) and (4231KS-A) to the proximity sensors on the fan cowl latches.
(d) Turn the proximity sensor harness (3) connectors (4233KS-A), (4232KS-A) and (4231KS-A) finger-tight. Turn the connectors 1/4 turn more with PLIERS - JAWED, SOFT.
(e) Put the 16 clamps (4) and clamp (6) on the proximity sensor harness (3).
(f) Install the 16 clamps (4) and proximity sensor harness (3) on the fan cowl door with the 16 bolts (5).
1 Do not torque the bolts (5) at this time.
(g) Install the clamp (6) and the proximity sensor harness (3) on the fan cowl door with the bolt (5).
1 Do not torque the bolt (5) at this time.
(h) Adjust the proximity sensor harness (3) to keep preload to a minimum. Make sure there are no kinks in the proximity sensor harness (3).
(i) TORQUE the bolts (5) to between 35 and 31.5 lbf.in (0.40 and 0.36 m.daN )
. (j) Connect the pylon harness connector (4056VC-A) to the proximity sensor harness (3) connector (4056VC).
(k) Turn the pylon harness connector (4056VC-A) finger-tight. Turn the connector 1/4 turn more with PLIERS - JAWED, SOFT.
CONFIGURATION 2
(3) Install the fan cowl latch proximity sensor harness (7).
(a) Attach the proximity sensor harness (7) connector (4056VC) to the disconnect bracket with the four screws (2) and four washers (1).
(b) Tighten the screws (2) by hand.
(c) Connect the proximity sensor harness (7) connectors (4233KS-A), (4232KS-A) and (4231KS-A) to the proximity sensors on the fan cowl latches.
(d) Turn the proximity sensor harness (7) connectors (4233KS-A), (4232KS-A) and (4231KS-A) finger-tight. Turn the connectors 1/4 turn more with PLIERS - JAWED, SOFT.
(e) Put the 14 clamps (8), two clamps (11) and clamp (12) on the proximity sensor harness (7).
(f) Install the 14 clamps (8) and proximity sensor harness (7) on the fan cowl door with the 14 washers (10) and 14 nuts (9).
1 Do not torque the nuts (9) at this time.
(g) Install the two clamps (11) and the proximity sensor harness (7) on the fan cowl door with the two washers (10) and two nuts (9).
1 Do not torque the nuts (9) at this time.
(h) Install the clamp (12) and the proximity sensor harness (7) on the fan cowl with the washer (10) and nut (9).
1 Do not torque the nut (9) at this time.
(i) Adjust the proximity sensor harness (7) to keep preload to a minimum. Make sure there are no kinks in the proximity sensor harness (7).
(j) TORQUE the nuts (9) to between 27 and 24 lbf.in (0.31 and 0.27 m.daN )
. (k) Connect the pylon harness connector (4056VC-A) to the proximity sensor harness (7) connector (4056VC).
(l) Turn the pylon harness connector (4056VC-A) finger-tight. Turn the connector 1/4 turn more with PLIERS - JAWED, SOFT.
Subtask 71-13-61-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
Subtask 71-13-61-865-052-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 71-13-61-710-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/LATCH DOORS & SLATS/ENG2 | 93KS2 | P40 |
| 121VU | ENGINE/LATCH DOORS & SLATS/ENG1 | 93KS1 | P39 |
C. Test(s)
(1) Do the Operational Test of the Fan Cowl Loss Prevention System Proximity Sensors (Ref. AMM TASK 71-13-00-710-802).
(1) Do the Operational Test of the Fan Cowl Loss Prevention System Proximity Sensors (Ref. AMM TASK 71-13-00-710-802).
Fan Cowl Latch Proximity Sensor Harness