Installation of the Lower Hold-Open-Rod Brackets at the B1 Flange [CFMI]
TASK 71-13-12-400-806-A
Installation of the Lower Hold-Open-Rod Brackets at the B1 Flange
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 71-13-12-941-065-A ** ON A/C NOT FOR ALL
Subtask 71-13-12-420-064-A ** ON A/C NOT FOR ALL
Subtask 71-13-12-410-057-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 02:22:27 UTC
Installation of the Lower Hold-Open-Rod Brackets at the B1 Flange
ZONE: 400
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | WARNING NOTICE(S) |
| No specific | Torque wrench: range to between 210 and 190 lbf.in (2.37 and 2.15 m.daN ) ![]() |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 400 | POWER PLANT, NACELLES AND PYLONS |
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-040-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-A | Closing of the Fan Cowl Doors |
Subtask 71-13-12-941-065-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(a) Put the WARNING NOTICE(S) in position to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than five minutes before you do this procedure.
(3) On overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put the WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 71-13-12-010-068-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on ENG panel 115VU:
(a) Put the WARNING NOTICE(S) in position to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than five minutes before you do this procedure.
(3) On overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put the WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
B. Aircraft Maintenance Configuration
(1) Make sure that the fan cowl-doors are open: (Ref. AMM TASK 71-13-00-010-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL, 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL, 448AR.
4. Procedure(1) Make sure that the fan cowl-doors are open: (Ref. AMM TASK 71-13-00-010-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL, 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL, 448AR.
Subtask 71-13-12-420-064-A ** ON A/C NOT FOR ALL
A. Installation of the Lower Hold-Open-Rod Brackets
(1) Install the right-lower hold-open-rod bracket (170):
(a) Install the brackets (160) and (170), bolts (130), washers (140) and nuts (150).
(b) TORQUE the nuts (150) to between 210 and 190 lbf.in (2.37 and 2.15 m.daN )
.
(2) Install the left-lower hold-open-rod bracket (580):
(a) Install the brackets (610) and (580), bolts (550), washers (560) and nuts (570).
(b) TORQUE the nuts (570) to between 210 and 190 lbf.in (2.37 and 2.15 m.daN )
.
5. Close-up(1) Install the right-lower hold-open-rod bracket (170):
(a) Install the brackets (160) and (170), bolts (130), washers (140) and nuts (150).
(b) TORQUE the nuts (150) to between 210 and 190 lbf.in (2.37 and 2.15 m.daN )
. (2) Install the left-lower hold-open-rod bracket (580):
(a) Install the brackets (610) and (580), bolts (550), washers (560) and nuts (570).
(b) TORQUE the nuts (570) to between 210 and 190 lbf.in (2.37 and 2.15 m.daN )
. Subtask 71-13-12-410-057-A ** ON A/C NOT FOR ALL
Lower Hold-Open-Rod Brackets