Removal of the Lower Hold-Open-Rod Brackets at the B1 Flange [CFMI]
TASK 71-13-12-000-806-A
Removal of the Lower Hold-Open-Rod Brackets at the B1 Flange
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 71-13-12-941-063-A ** ON A/C NOT FOR ALL
Subtask 71-13-12-020-062-A ** ON A/C NOT FOR ALL
Subtask 71-13-12-410-059-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 02:22:26 UTC
Removal of the Lower Hold-Open-Rod Brackets at the B1 Flange
ZONE: 400
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 400 | POWER PLANT, NACELLES AND PYLONS |
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-040-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-A | Closing of the Fan Cowl Doors |
Subtask 71-13-12-941-063-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(a) Put the WARNING NOTICE(S) in position to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than five minutes before you do this procedure.
(3) On overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put the WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 71-13-12-010-067-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on ENG panel 115VU:
(a) Put the WARNING NOTICE(S) in position to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than five minutes before you do this procedure.
(3) On overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put the WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
B. Get Access
(1) Open the fan cowl-doors: (Ref. AMM TASK 71-13-00-010-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL, 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL, 448AR.
4. Procedure(1) Open the fan cowl-doors: (Ref. AMM TASK 71-13-00-010-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL, 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL, 448AR.
Subtask 71-13-12-020-062-A ** ON A/C NOT FOR ALL
A. Removal of the Lower Hold-Open-Rod Brackets
(1) Remove the right-lower hold-open-rod bracket (170):
(a) Remove the nuts (150), bolts (130), washers (140), brackets (160) and (170).
(2) Remove the left-lower hold-open-rod bracket (580):
(a) Remove the nuts (570), bolts (550), washers (560), brackets (610) and (580).
5. Close-up(1) Remove the right-lower hold-open-rod bracket (170):
(a) Remove the nuts (150), bolts (130), washers (140), brackets (160) and (170).
(2) Remove the left-lower hold-open-rod bracket (580):
(a) Remove the nuts (570), bolts (550), washers (560), brackets (610) and (580).
Subtask 71-13-12-410-059-A ** ON A/C NOT FOR ALL
Lower Hold-Open-Rod Brackets