W DOC AIRBUS | AMM A320F

Visual Inspection of the Fan Cowl Doors [CFMI]


TASK 71-13-11-200-804-A
Visual Inspection of the Fan Cowl Doors


1. Reason for the Job
Refer to the MPD TASK: 711000-C4
GENERAL VISUAL INSPECTION OF FAN COWL DOORS
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
1
FLASHLIGHT
No specific
1
MAGNIFYING GLASS POWER 10X
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-040-A
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-A
Closing of the Fan Cowl Doors
NSRM 542000
3. Job Set-up
Subtask 71-13-11-941-073-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 71-13-11-010-069-A ** ON A/C NOT FOR ALL
B. Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
   (1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
   (2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (3) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
4. Procedure
Subtask 71-13-11-210-069-A ** ON A/C NOT FOR ALL
A. General Visual Inspection of the Fan Cowl Doors
   (1) Do a general visual inspection of the internal and external surfaces of the Fan Cowl Doors. If necessary, you can use the FLASHLIGHT and the MAGNIFYING GLASS POWER 10X.
   (2) Make sure that there are no signs of damage (cracks corrosion, dents, or disbond).
     (a) If you find damage, look for damage limits and do the applicable repair procedure. Refer to NSRM 542000.
5. Close-up
Subtask 71-13-11-410-064-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (3) Remove the access platform(s).
   (4) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 02:22:20 UTC