General Visual Inspection of Fan Cowl Door Fire Seals [CFMI]
TASK 71-13-11-200-802-A
General Visual Inspection of Fan Cowl Door Fire Seals
1. Reason for the Job
Refer to the MPD TASK: 711000-C7
GENERAL VISUAL INSPECTION OF FAN COWL DOOR FIRE SEALS
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 71-13-11-941-068-A ** ON A/C NOT FOR ALL
Subtask 71-13-11-210-066-A ** ON A/C NOT FOR ALL
Subtask 71-13-11-410-059-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 02:22:18 UTC
General Visual Inspection of Fan Cowl Door Fire Seals
1. Reason for the Job
Refer to the MPD TASK: 711000-C7
GENERAL VISUAL INSPECTION OF FAN COWL DOOR FIRE SEALS
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-040-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-A | Closing of the Fan Cowl Doors |
Subtask 71-13-11-941-068-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) warning notice in position to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than five minutes before you do this procedure.
(3) On the ENG section of the maintenance panel 50VU:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) warning notice in position to tell persons not to energize the FADEC 1(2).
Subtask 71-13-11-010-062-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) warning notice in position to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than five minutes before you do this procedure.
(3) On the ENG section of the maintenance panel 50VU:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) warning notice in position to tell persons not to energize the FADEC 1(2).
B. Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(1) FOR [1000EM1] (ENGINE-1)
437AL, 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL, 448AR
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
437AL, 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL, 448AR
Subtask 71-13-11-210-066-A ** ON A/C NOT FOR ALL
A. General Visual Inspection on the Fan Cowl Door Fire Seals
5. Close-up| INSPECT/CHECK | MAXIMUM SERVICEABLE LIMITS | REMARKS |
|---|---|---|
| 1. Examine the fan cowl door fire seals for: | | |
| A. Damage | None allowed. | If damage is found, replace the fire seal |
| B. Cut | None allowed. | If a cut is found, replace the fire seal |
| C. Missing seal | None allowed. | Replace the missing fire seal |
| D. Missing fasteners | None allowed. | Replace the missing fasteners |
| E. Misalignment | None allowed. | Align or replace the fire seal |
Subtask 71-13-11-410-059-A ** ON A/C NOT FOR ALL
Fan Cowl Door Fire Seals