SPS 87 - Gaspath/Compressor Solution [PW11]
TASK 70-27-00-910-803-A
SPS 87 - Gaspath/Compressor Solution
Self explanatory
2. Job Set-up Information
A. Consumable Materials
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 70-27-00-941-050-A ** ON A/C NOT FOR ALL
Subtask 70-27-00-110-051-A ** ON A/C NOT FOR ALL
(3) Use SPS 87 Gaspath or Compressor Solution (Material No.P11-021) at ambient temperature unless the manufacturer's instructions specify differently.
[Rev.10 from 2021]
2026.04.01 12:54:24 UTC
SPS 87 - Gaspath/Compressor Solution
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 400
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Consumable Materials
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.P11-021) | SPS 87 Gaspath or Compressor Solution |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 400 | POWER PLANT, NACELLES AND PYLONS |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 70-27-00-910-802-A | Potable Water for Compressor Wash |
Subtask 70-27-00-941-050-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. ProcedureSubtask 70-27-00-110-051-A ** ON A/C NOT FOR ALL
WARNING:
REFER TO THE MANUFACTURER'S MATERIAL SAFETY DATA SHEETS FOR CONSUMABLE MATERIAL INFORMATION. THIS INCLUDES HAZARDOUS INGREDIENTS, PHYSICAL AND CHEMICAL CHARACTERISTICS, FIRE, EXPLOSION, REACTIVITY, HEALTH HAZARD DATA, PRECAUTIONS FOR SAFE HANDLING, AND USE OF CONTROL MEASURES.
A. General Instructions NOTE: Always obey the specific procedures and limits in the AMM maintenance tasks.
(1) Make-up of SPS 87 Gaspath or Compressor Solution (Material No.P11-021) NOTE: SPMC 87-1, SPMC 87-2, SPMC 87-3, SPMC 87-4, SPMC 87-6, SPMC 87-7, SPMC 87-8, and SPMC 87-12 are not available; there are no replacements.
| Materials | Make-Up |
|---|---|
| Gaspath/Compressor Cleaner | 20 percent by volume with potable water |
| (SPMC 87-10A, SPMC 87-11C, SPMC 87-13 or SPMC 87-14) | |
| or | |
| Gaspath/Compressor Cleaner | 10 percent by volume with potable water |
| (SPMC 87-11A) | |
| or | |
| Gaspath/Compressor Cleaner | 100 percent by volume |
| (SPMC 87-5, SPMC 87-9A, SPMC 87-10B or SPMC 87-11B) | |
| or | |
| Gaspath/Compressor Cleaner | 15 percent by volume with potable water |
| (SPMC 87-9B) | |
NOTE: Refer to the potable water quality specifications in special cleaning quality control (Ref. AMM TASK 70-27-00-910-802).
(2) Mix as specified in the applicable gaspath/compressor cleaning cart. (3) Use SPS 87 Gaspath or Compressor Solution (Material No.P11-021) at ambient temperature unless the manufacturer's instructions specify differently.