Potable Water for Compressor Wash [PW11]
TASK 70-27-00-910-802-A
Potable Water for Compressor Wash
Self explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 70-27-00-869-051-A ** ON A/C NOT FOR ALL
Subtask 70-27-00-910-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 12:54:24 UTC
Potable Water for Compressor Wash
ZONE: 400
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 400 | POWER PLANT, NACELLES AND PYLONS |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 70-27-00-910-803-A | SPS 87 - Gaspath/Compressor Solution |
Subtask 70-27-00-869-051-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. ProcedureSubtask 70-27-00-910-051-A ** ON A/C NOT FOR ALL
A. Potable water quality specifications (compressor wash):
(1) Always obey the specific procedures and limits in the Aircraft Maintenance Manuel (AMM) maintenance task.
(a) Water used for engine gaspath cleaning must agree with local quality specifications for potable water and with the quality specifications that follows:
(1) Always obey the specific procedures and limits in the Aircraft Maintenance Manuel (AMM) maintenance task.
NOTE: Maintenance manuals use potable water for rinsing after detergent washing.
NOTE: SPS 87 gaspath/compressor solution uses potable water in its make-up. For the make-up of this solution, you can refer to (Ref. AMM TASK 70-27-00-910-803).
(2) The quality specifications for potable water suitable for engine gaspath cleaning are as follows: (a) Water used for engine gaspath cleaning must agree with local quality specifications for potable water and with the quality specifications that follows:
NOTE: When the local quality specifications for potable water and quality specifications that follow do not agree, the quality specifications that follow are applicable.
| Property | Permitted Levels |
|---|---|
| Physical properties (analysis at 75 deg.F (24 deg.C)): | |
| pH | 6.0 - 10.0 |
| Total dissolved solids | 500 mg/l maximum |
| Specific resistance | 1800 ohms-cm minimum |
| Or | |
| Conductivity | 550 microsiemens/cm maximum |
| Inorganic content: | |
| Chlorides | 250 mg/l maximum |
| Fluoride | 2.0 mg/l maximum |
Table - Potable water quality specifications (compressor wash)