Removal of the Closing Sheet Metal
TASK 54-54-00-000-805-A
Removal of the Closing Sheet Metal
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 54-54-00-941-068-A ** ON A/C NOT FOR ALL
Subtask 54-54-00-020-081-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 02:02:54 UTC
Removal of the Closing Sheet Metal
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
1. Reason for the Job- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | SCRAPER - NON METALLIC |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 470 | ENGINE 1 AFT PYLON |
| 480 | ENGINE 2 AFT PYLON |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-00-00-860-833-A | Procedure to Prevent Engine Motoring |
| TASK 78-30-00-040-805-A | Deactivation of the Thrust Reverser System for Ground Maintenance |
Subtask 54-54-00-941-068-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
Subtask 54-54-00-040-064-A ** ON A/C NOT FOR ALL (1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
B. Deactivation of the Thrust Reverser
Subtask 54-54-00-010-063-A ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER IS LOCKED. IF NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE REVERSER.
(1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-040-805). C. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position:
(a) For the left pylon, at zone 470
(b) For the right pylon, at zone 480.
4. Procedure(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position:
(a) For the left pylon, at zone 470
(b) For the right pylon, at zone 480.
Subtask 54-54-00-020-081-A ** ON A/C NOT FOR ALL
A. Removal of the Closing Sheet Metal
(2) Remove the closing sheet metal (5).
(3) With the SCRAPER - NON METALLIC, remove the sealant from:
(a) The inner side of the closing sheet metal (5)
(b) The area around the drain pipes where they touch the closing sheet metal (5).
CAUTION:
WHEN YOU REMOVE THE SCREWS, MAKE SURE THAT YOU RECORD THE CORRECT POSITION OF EACH OF THEM. THE SCREWS HAVE DIFFERENT LENGTHS.
(1) Remove the screws (1), (2), (3) and (4). (2) Remove the closing sheet metal (5).
(3) With the SCRAPER - NON METALLIC, remove the sealant from:
(a) The inner side of the closing sheet metal (5)
(b) The area around the drain pipes where they touch the closing sheet metal (5).
Closing Sheet Metal