W DOC AIRBUS | AMM A320F

Removal of the Closing Sheet Metal


TASK 54-54-00-000-805-A
Removal of the Closing Sheet Metal


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
ZONE: 470
ZONE: 480
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
AR
SCRAPER - NON METALLIC
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
470
ENGINE 1 AFT PYLON
480
ENGINE 2 AFT PYLON
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-00-00-860-833-A
Procedure to Prevent Engine Motoring
TASK 78-30-00-040-805-A
Deactivation of the Thrust Reverser System for Ground Maintenance
3. Job Set-up
Subtask 54-54-00-941-068-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
Subtask 54-54-00-040-064-A ** ON A/C NOT FOR ALL
B. Deactivation of the Thrust Reverser
WARNING: MAKE SURE THAT THE THRUST REVERSER IS LOCKED. IF NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE REVERSER.
   (1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-040-805).
Subtask 54-54-00-010-063-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position:
     (a) For the left pylon, at zone 470
     (b) For the right pylon, at zone 480.
4. Procedure
Subtask 54-54-00-020-081-A ** ON A/C NOT FOR ALL
A. Removal of the Closing Sheet Metal
F Closing Sheet Metal ** ON A/C NOT FOR ALL
CAUTION: WHEN YOU REMOVE THE SCREWS, MAKE SURE THAT YOU RECORD THE CORRECT POSITION OF EACH OF THEM. THE SCREWS HAVE DIFFERENT LENGTHS.
   (1) Remove the screws (1), (2), (3) and (4).
   (2) Remove the closing sheet metal (5).
   (3) With the SCRAPER - NON METALLIC, remove the sealant from:
     (a) The inner side of the closing sheet metal (5)
     (b) The area around the drain pipes where they touch the closing sheet metal (5).
[Rev.10 from 2021] 2026.04.01 02:02:54 UTC