Removal of the Pressure Relief Door
TASK 54-53-11-000-001-A
Removal of the Pressure Relief Door
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 54-53-11-941-050-A ** ON A/C NOT FOR ALL
Subtask 54-53-11-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 02:02:24 UTC
Removal of the Pressure Relief Door
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
1. Reason for the Job- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 470 | ENGINE 1 AFT PYLON |
| 480 | ENGINE 2 AFT PYLON |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 78-30-00-040-012-A | Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance |
| TASK 78-30-00-481-041-A | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-30-00-481-041-B | Make the Thrust Reverser Unserviceable for Maintenance |
Subtask 54-53-11-941-050-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 54-53-11-010-052-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
B. Get Access
(1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position :
(a) at the zone 470 for the left pylon.
(b) at the zone 480 for the right pylon.
Subtask 54-53-11-040-050-A ** ON A/C NOT FOR ALL (1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position :
(a) at the zone 470 for the left pylon.
(b) at the zone 480 for the right pylon.
C. Aircraft Maintenance Configuration
(1) Make the thrust reverser unserviceable (Ref. AMM TASK 78-30-00-481-041).
Subtask 54-53-11-040-050-B ** ON A/C NOT FOR ALL (1) Make the thrust reverser unserviceable (Ref. AMM TASK 78-30-00-481-041).
C. Aircraft Maintenance Configuration
(1) Make the thrust reverser unserviceable (Ref. AMM TASK 78-30-00-040-012).
4. Procedure(1) Make the thrust reverser unserviceable (Ref. AMM TASK 78-30-00-040-012).
Subtask 54-53-11-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Pressure Relief Door
(1) Remove the eight screws (5) and washers (6).
(2) Remove the panel (9).
(3) Remove the nuts (8) and the screws (1).
(4) Remove the nuts (7), the screws (4) and the washers (3).
(5) Remove the pressure relief door (2).
Subtask 54-53-11-020-050-B ** ON A/C NOT FOR ALL (1) Remove the eight screws (5) and washers (6).
(2) Remove the panel (9).
(3) Remove the nuts (8) and the screws (1).
(4) Remove the nuts (7), the screws (4) and the washers (3).
(5) Remove the pressure relief door (2).
A. Removal of the Pressure Relief Door
(1) Remove the four screws (1) and washers (2).
(2) Remove the pressure relief door (3).
(1) Remove the four screws (1) and washers (2).
(2) Remove the pressure relief door (3).
Pressure Relief Door