Removal of the Bulk Cargo-Compartment Floor-Panels
TASK 53-42-17-000-001-A
Removal of the Bulk Cargo-Compartment Floor-Panels
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 53-42-17-010-050-A ** ON A/C NOT FOR ALL
Subtask 53-42-17-020-051-A
[Rev.10 from 2021]
2026.04.01 01:57:29 UTC
Removal of the Bulk Cargo-Compartment Floor-Panels
NOTE: For the FINs of the bulk cargo-compartment floor-panels, refer to DO 06-41-53-00.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | 1 | SCRAPER - NON METALLIC |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 162KF |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-006-A | Open the Bulk Cargo-Compartment Door |
| TASK 52-71-12-000-003-A | Removal of the Proximity Switch |
Subtask 53-42-17-010-050-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Open the AFT cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
(2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the AFT cargo-compartment door.
Subtask 53-42-17-010-050-B ** ON A/C NOT FOR ALL (1) Open the AFT cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
(2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the AFT cargo-compartment door.
A. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the BULK cargo-compartment door.
(2) Open the BULK cargo-compartment door (Ref. AMM TASK 52-30-00-860-006).
(3) For panel 162KF remove the Proximity Switch 50WV (Ref. AMM TASK 52-71-12-000-003).
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the BULK cargo-compartment door.
(2) Open the BULK cargo-compartment door (Ref. AMM TASK 52-30-00-860-006).
(3) For panel 162KF remove the Proximity Switch 50WV (Ref. AMM TASK 52-71-12-000-003).
Subtask 53-42-17-020-051-A
A. Remove the Floor Panels
(1) Find the end of the cord (4).
(2) Pull the cord up to remove the sealant from between the floor panels (2).
(3) Remove the sealant from between the cutouts and the tiedown positions with a SCRAPER - NON METALLIC.
(4) Remove the screws (1).
(5) Remove the floor panels (2) and the seals (3), (5), (6) and (7).
(1) Find the end of the cord (4).
(2) Pull the cord up to remove the sealant from between the floor panels (2).
(3) Remove the sealant from between the cutouts and the tiedown positions with a SCRAPER - NON METALLIC.
(4) Remove the screws (1).
(5) Remove the floor panels (2) and the seals (3), (5), (6) and (7).
Bulk Cargo-Compartment Floor-Panels - Zone 160