General Visual Inspection of APU Compartment Drain System (APS 3200)
TASK 49-17-00-200-805-A
General Visual Inspection of APU Compartment Drain System (APS 3200)
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 49-17-00-860-056-A ** ON A/C NOT FOR ALL
Subtask 49-17-00-210-052-A ** ON A/C NOT FOR ALL
Subtask 49-17-00-410-057-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:28:25 UTC
General Visual Inspection of APU Compartment Drain System (APS 3200)
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
WARNING:
DO NOT TOUCH THE APU UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | 1 | PROBE - NON METALLIC, FLEXIBLE |
| No specific | 1 | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08ABC1) | Aqueous Cleaner-Aircraft Exterior Pressure Spraying - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 315AL, 316AR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 52-41-00-010-001-A | Open the APU Doors for Access |
| TASK 52-41-00-410-001-A | Close the APU Doors after Access |
Subtask 49-17-00-860-056-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Put a WARNING NOTICE(S) in the cockpit to tell persons not to start the APU.
Subtask 49-17-00-010-057-A ** ON A/C NOT FOR ALL (1) Put a WARNING NOTICE(S) in the cockpit to tell persons not to start the APU.
B. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) in position below the APU compartment.
(2) Open APU access doors 315AL and 316AR (Ref. AMM TASK 52-41-00-010-001).
(3) Set the LIGHT control SW 11LJ to the ON position.
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) in position below the APU compartment.
(2) Open APU access doors 315AL and 316AR (Ref. AMM TASK 52-41-00-010-001).
(3) Set the LIGHT control SW 11LJ to the ON position.
Subtask 49-17-00-210-052-A ** ON A/C NOT FOR ALL
A. General Visual Inspection of APU Compartment Drain System
(1) Clean the area around the drain holes with a Textile-Lint free Cotton - (Material No.14SBA1) and Aqueous Cleaner-Aircraft Exterior Pressure Spraying - (Material No.08ABC1) .
(2) Examine the drain holes for blockage. If necessary, remove the blockage.
(3) If you find blockage into the drain mast, use a PROBE - NON METALLIC, FLEXIBLE to make sure that the drain pipe is not blocked.
(4) If the drain pipe is blocked, remove the blockage.
(5) Make sure that the drains are not blocked:
(a) Put water in the area of the drain hole and make sure that the water flows freely at the drain mast outlet.
(6) Make sure that the drain mast is correctly aligned.
5. Close-up(1) Clean the area around the drain holes with a Textile-Lint free Cotton - (Material No.14SBA1) and Aqueous Cleaner-Aircraft Exterior Pressure Spraying - (Material No.08ABC1) .
(2) Examine the drain holes for blockage. If necessary, remove the blockage.
(3) If you find blockage into the drain mast, use a PROBE - NON METALLIC, FLEXIBLE to make sure that the drain pipe is not blocked.
(4) If the drain pipe is blocked, remove the blockage.
(5) Make sure that the drains are not blocked:
(a) Put water in the area of the drain hole and make sure that the water flows freely at the drain mast outlet.
(6) Make sure that the drain mast is correctly aligned.
Subtask 49-17-00-410-057-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Set the LIGHT control SW 11LJ to the OFF position.
(3) Close APU access doors 315AL and 316AR (Ref. AMM TASK 52-41-00-410-001).
(4) Remove the access platform(s).
Subtask 49-17-00-860-057-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Set the LIGHT control SW 11LJ to the OFF position.
(3) Close APU access doors 315AL and 316AR (Ref. AMM TASK 52-41-00-410-001).
(4) Remove the access platform(s).
B. Aircraft Maintenance Configuration
(1) Remove the WARNING NOTICE(S).
(1) Remove the WARNING NOTICE(S).