W DOC AIRBUS | AMM A320F

Deactivation of the APU Air Intake Flap (APS 3200)


TASK 49-16-00-040-002-A
Deactivation of the APU Air Intake Flap (APS 3200)


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION: MAKE SURE THAT THE AIR INTAKE FLAP IS FULLY EXTENDED BEFORE YOU INSTALL THE TEMPORARY CONNECTOR. IF NOT, YOU WILL CAUSE DAMAGE TO THE APU.
ZONE: 313
ZONE: 314
Task Summary
Access Test Specific Tools Mhr E/T Nb Men
YESNONO0.50.51
1. Reason for the Job
MMEL 49-10-02B
APU AIR INTAKE FLAP
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE
No specific
AR
BACKSHELL ABS0638A14
No specific
AR
CAP - BLANKING
No specific
AR
CONNECTOR E0052R14B12PNE
No specific
1
FLASHLIGHT
No specific
AR
JUMPER-WIRE
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
TIE WRAP
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.04JAA3)
Top Coat Polyurethane_- - External Structure
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
313
TAIL CONE APU AIR INTAKE AREA
314
TAIL CONE APU AIR INTAKE AREA
314AR
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 49-16-43-000-005-A
Removal of the Catwalk Panel (APS3200)
TASK 49-16-43-400-005-A
Installation of the Catwalk Panel (APS3200)
TASK 52-41-23-010-801-A
Opening of Access Door 314AR
TASK 52-41-23-410-801-A
Closing of Access Door 314AR
ESPM 2044110
AIPC 24-92-04-67
AIPC 24-92-04-72
3. Job Set-up
Subtask 49-16-00-010-054-A ** ON A/C NOT FOR ALL
A. Get Access
WARNING: BEFORE YOU START WORK, YOU MUST PUT ON A SAFETY HARNESS AND ATTACH IT TO THE ACCESS PLATFORM. WITHOUT A SAFETY HARNESS, YOU CAN FALL. THIS CAN KILL YOU OR CAUSE YOU INJURY.
   (1) Put on and attach a safety harness before you start work in the work area
   (2) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE below access door 314AR.
   (3) Open access door 314AR and safety it in the open position.
(Ref. AMM TASK 52-41-23-010-801).
   (4) If necessary, use a FLASHLIGHT.
   (5) Remove the catwalk panel (Ref. AMM TASK 49-16-43-000-005).
Subtask 49-16-00-865-058-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUAPU/APU/CTL2KDL42
121VUAPU/ECB/SPLY1KDL41
4. Procedure
Subtask 49-16-00-040-050-A ** ON A/C NOT FOR ALL
A. Deactivation of the Air Intake Flap
   (1) Disconnect the electrical connectors 7527VC-A and 7527VC.
     (a) Disconnect the electrical connector 7527VC-A from the connector 7527VC.
     (b) Put a CAP - BLANKING on the electrical connector 7527VC.
     (c) Attach the electrical connector 7527VC-A to the air intake structure with a TIE WRAP.
   (2) Open the air intake flap manually if it is not fully extended.
     (a) Turn the manual drive shaft on the air intake flap-actuator 4015KM until the air intake flap is fully extended.
NOTE: Make sure that the torque necessary to turn the manual drive shaft is not more than 0.3 m.daN (26.55 lbf.in) for the actuator 43-1-1100 Amendment 1, for the actuator 106-1-1100-02 not more than 0.4 m.daN (35.40 lbf.in). Be careful when you come to the mechanical stop at the end of travel. If you turn the manual drive shaft with more torque than the limit, damage to the air intake flap actuator will occur.

NOTE: On the actuator 43-1-1100-Amendment 1, 47 turns are required for one full travel of the air intake flap actuator. On the actuator 106-1-1100 -02, 87 turns are required.
     (b) Make sure that the air intake flap is fully extended.
   (3) Make a temporary connector with a jumper lead to close the ''FLAP OPEN'' and the ''FLAP CLOSE'' control circuit between the ECB 59KD and the air intake-flap actuator 4015KM.
     (a) Connect a JUMPER-WIRE between the pins C and D of a CONNECTOR E0052R14B12PNE.
     (b) Hold the jumper lead in position on the connector with a BACKSHELL ABS0638A14.
     (c) Paint the temporary connector red with Top Coat Polyurethane_- - External Structure (Material No.
04JAA3) to make sure that it is easily identified.
   (4) Connect the temporary connector to the connector 7527VC-A.
   (5) Make an entry in the logbook.
5. Close-up
Subtask 49-16-00-410-054-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Install the catwalk panel (Ref. AMM TASK 49-16-43-400-005).
   (2) Make sure that the work area is clean and clear of tools and other items.
   (3) Close access door 314AR (Ref. AMM TASK 52-41-23-410-801).
   (4) Remove the access platform(s).
Subtask 49-16-00-865-059-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUAPU/APU/CTL2KDL42
121VUAPU/ECB/SPLY1KDL41
[Rev.10 from 2021] 2026.04.01 01:27:33 UTC