W DOC AIRBUS | AMM A320F

Inspection/Check of the Full-Face Smoke Mask


TASK 35-32-51-210-001-A
Inspection/Check of the Full-Face Smoke Mask


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 35-32-51-110-001-A
Cleaning of the Full-Face Smoke Mask
3. Job Set-up
Subtask 35-32-51-010-050-A ** ON A/C NOT FOR ALL
A. Get access.
   (1) Remove the full-face smoke masks from their stowage containers.
4. Procedure
WARNING: KEEP ALL HYDROCARBONS (FUELS, LUBRICANTS, ETC.) AWAY FROM ALL SOURCE OF OXYGEN. OXYGEN BECOMES EXPLOSIVE WHEN IT TOUCHES HYDROCARBONS.
WARNING: CLEAN THE TOOLS AND MAKE SURE YOUR HANDS ARE CLEAN TO PREVENT CONTAMINATION OF THE OXYGEN SYSTEM.
Subtask 35-32-51-020-050-A ** ON A/C NOT FOR ALL
A. If necessary, clean the full-face smoke masks (Ref. AMM TASK 35-32-51-110-001).
Subtask 35-32-51-210-052-A ** ON A/C NOT FOR ALL
B. Visual Inspection. Do a visual inspection of the full-face smoke masks and make sure that the items that follow are serviceable:
  • The panoramic visor and the moulded-rubber face piece,
  • The adjustable head straps,
  • The demand regulator,
  • The flexible hose and the hose connector,
  • The exhaust valve.
  • The stowage containers of the smoke masks.
5. Close-up
Subtask 35-32-51-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Put the full-face smoke masks in their stowage containers.
[Rev.9 from 2019] 2026.04.01 12:37:01 UTC