W DOC AIRBUS | AMM A320F

Cleaning of the Passenger Oxygen Mask


TASK 35-21-43-100-001-A
Cleaning of the Passenger Oxygen Mask


WARNING: KEEP ALL HYDROCARBONS (FUELS, LUBRICANTS, ETC.) AWAY FROM ALL SOURCE OF OXYGEN. OXYGEN BECOMES EXPLOSIVE WHEN IT TOUCHES HYDROCARBONS.
WARNING: CLEAN THE TOOLS AND MAKE SURE YOUR HANDS ARE CLEAN TO PREVENT CONTAMINATION OF THE OXYGEN SYSTEM.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION: DO NOT PULL THE MASK LANYARD FROM THE END WITH THE RELEASE PIN. IF YOU PULL ON THIS END OF THE LANYARD, YOU WILL REMOVE THE RELEASE PIN AND START A FLOW OF OXYGEN WHICH CANNOT BE STOPPED.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
BRUSH - BRISTLED, SOFT
995000-00
1
TOOL-MANUAL RELEASE
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.11CKA1)
Disinfectant and cleaner-Oxygen Mask - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 35-21-43-550-801-A
Packing of the Oxygen Mask Assemblies
3. Job Set-up
Subtask 35-21-43-910-050-A
A. Preparation for Cleaning
   (1) Put the 995000-00 TOOL-MANUAL RELEASE into the access hole in the applicable door.
NOTE: It is permitted to use alternative tool P/N 995000.
   (2) Push the tool in until the latch is released. The door opens and the masks fall out.
   (3) Prepare the cleaning solution:
  • Mix 1.5cc (0.91in3) of the Disinfectant and cleaner-Oxygen Mask - - (Material No.11CKA1) with 4 liters (1.05USgal) of clean water.
4. Procedure
Subtask 35-21-43-110-050-A
A. Cleaning of the mask, the harness and the mask stowage box
CAUTION: DO NOT PULL THE MASK LANYARD FROM THE END WITH THE RELEASE PIN. IF YOU PULL ON THIS END OF THE LANYARD, YOU WILL REMOVE THE RELEASE PIN AND START A FLOW OF OXYGEN WHICH CANNOT BE STOPPED.
   (1) Clean the mask and the harness with the cleaning solution and a BRUSH - BRISTLED, SOFT or a cloth.
   (2) Flush with clean water. Rub with Textile-Lint free Cotton - (Material No.14SBA1) and let the mask dry in the air.
   (3) Clean the stowage box with Textile-Lint free Cotton - (Material No.14SBA1) .
5. Close-up
Subtask 35-21-43-420-051-A
A. Put the aircraft back to its initial configuration.
   (1) Install the passenger oxygen mask (Ref. AMM TASK 35-21-43-550-801).
[Rev.10 from 2021] 2026.04.01 01:05:07 UTC