W DOC AIRBUS | AMM A320F

Removal of the Photoluminescent Strip of the Floor-Proximity Emergency-Escape Path-Marking


TASK 33-51-21-000-001-A
Removal of the Photoluminescent Strip of the Floor-Proximity Emergency-Escape Path-Marking


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
SCRAPER - NON METALLIC
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
3. Job Set-up
Subtask 33-51-21-860-050-A ** ON A/C NOT FOR ALL
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
4. Procedure
Subtask 33-51-21-020-050-I ** ON A/C NOT FOR ALL
A. Removal of the Photoluminescent Strip of the Floor-Proximity Emergency-Escape Path-Marking
   (1) Remove the carpet protector (7) from the photoluminescent strip (1).
   (2) Remove the sealant (2) from the area that is between the non-textile floor covering and the photoluminescent strip (1) with the SCRAPER - NON METALLIC.
   (3) Remove the photoluminescent strip (1) together with the adhesive tape (3) and the end-cap (6) (if installed) from the floor panels.
   (4) Use the SCRAPER - NON METALLIC for the removal procedure.
   (5) If necessary, remove the sealant from the end-cap (6) with the SCRAPER - NON METALLIC.
   (6) Remove the end-cap (6) from the photoluminescent strip (1).
Subtask 33-51-21-020-050-AK ** ON A/C NOT FOR ALL
A. Removal of the Photoluminescent Strip of the Floor-Proximity Emergency-Escape Path-Marking
   (1) You must use a SCRAPER - NON METALLIC to help the removal procedure.
   (2) Remove the clip (1) from the photoluminescent strips (2).
   (3) Remove the sealant (4) between the non-textile floor covering and the photoluminescent strips (2) with a SCRAPER - NON METALLIC.
   (4) Remove the photoluminescent strips (2).
   (5) Remove the filler (3), if necessary.
Subtask 33-51-21-020-050-AV ** ON A/C NOT FOR ALL
A. Removal of the Photoluminescent Strips of the Floor-Proximity Emergency-Escape Path-Marking
   (1) Remove the photoluminescent strips (3) and (5) as follows:
     (a) If necessary, remove the sealant from the end-cap clips (4) and the end-caps (7) with the SCRAPER - NON METALLIC.
     (b) Remove the end-cap clips (4) and the end-caps (7).
     (c) Remove the clips (1) from the photoluminescent strip (3).
     (d) Remove the sealant (6) from the area that is between the non-textile floor covering and the photoluminescent strip (5) with the SCRAPER - NON METALLIC.
     (e) Remove the filter films (2) from the photoluminescent strip (3).
     (f) Remove the photoluminescent strips (3) and (5).
Subtask 33-51-21-020-050-AZ ** ON A/C NOT FOR ALL
A. Removal of the Photoluminescent Strips of the Floor-Proximity Emergency-Escape Path-Marking
   (1) Remove the photoluminescent strips (2) and (5) as follows:
     (a) If necessary, remove the sealant from the end-cap clips (3) and the end-caps (7) with the SCRAPER - NON METALLIC.
     (b) Remove the end-cap clips (3) and the end-caps (7).
     (c) Remove the clips (1) from the photoluminescent strip (2).
     (d) Remove the sealant (6) from the area that is between the non-textile floor covering and the photoluminescent strips (2) and (5) with the SCRAPER - NON METALLIC.
     (e) Remove the photoluminescent strips (2) and (5).
   (2) If necessary, remove the filler (4).
Subtask 33-51-21-020-050-BB ** ON A/C NOT FOR ALL
A. Removal of the Photoluminescent Strip of the Floor-Proximity Emergency-Escape Path-Marking
   (1) Remove the sealant (2) between the floor covering and the photoluminescent strip (1) with a SCRAPER - NON METALLIC.
   (2) Remove the photoluminescent strip (1) from the floor panels. Use a SCRAPER - NON METALLIC to help the removal procedure.
   (3) Remove the filler (3) together with the photoluminescent strip (1), if installed.
Subtask 33-51-21-020-050-BC ** ON A/C NOT FOR ALL
A. Removal of the Photoluminescent Strip of the Floor-Proximity Emergency-Escape Path-Marking
NOTE: You can use the SCRAPER - NON METALLIC for the removal procedure.
   (1) Remove the photoluminescent strip (3) as follows:
     (a) If necessary, remove the sealant from the end-cap clips (5) with the SCRAPER - NON METALLIC.
     (b) Remove the end-cap clips (5).
     (c) Remove the clips (1) from the photoluminescent strip (3).
     (d) Remove the sealant (6) from the area that is between the non-textile floor covering and the photoluminescent strip (3) with the SCRAPER - NON METALLIC.
     (e) Remove the filter films (2) (if installed).
     (f) Remove the photoluminescent strip (3).
   (2) If necessary, remove the filler (4).
[Rev.10 from 2021] 2026.04.01 12:34:13 UTC