Installation of the Integrally-Lighted Identification Plate
TASK 33-13-44-400-801-A
Installation of the Integrally-Lighted Identification Plate
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 33-13-44-865-051-A
Subtask 33-13-44-420-050-A
Subtask 33-13-44-942-050-A
[Rev.10 from 2021]
2026.04.01 00:52:56 UTC
Installation of the Integrally-Lighted Identification Plate
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| 211 | COCKPIT |
| 212 | COCKPIT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 33-13-00-710-001-A | Operational Test of the Instrument and Panel Integral-Lighting |
Subtask 33-13-44-865-051-A
A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | LIGHTING/INSTL LT/GLARE/SHLD | 5LF | Y05 |
Subtask 33-13-44-420-050-A
A. Installation of the Integrally-Lighted Identification Plate (33LF)
(1) Put the integrally-lighted identification plate (3) in position on the CAPTAIN glareshield panel 131VU (1).
(2) Install and tighten the four screws (2).
(3) Push the CAPTAIN glareshield panel 131VU (1).
Subtask 33-13-44-420-051-A (1) Put the integrally-lighted identification plate (3) in position on the CAPTAIN glareshield panel 131VU (1).
(2) Install and tighten the four screws (2).
(3) Push the CAPTAIN glareshield panel 131VU (1).
B. Installation of the Integrally-Lighted Identification Plate (32LF)
(1) Put the integrally-lighted identification plate (5) in position on the F/O glareshield panel 130VU (4).
(2) Install and tighten the four screws (6).
(3) Push the F/O glareshield panel 130VU (4).
Subtask 33-13-44-865-052-A (1) Put the integrally-lighted identification plate (5) in position on the F/O glareshield panel 130VU (4).
(2) Install and tighten the four screws (6).
(3) Push the F/O glareshield panel 130VU (4).
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 33-13-44-710-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | LIGHTING/INSTL LT/GLARE/SHLD | 5LF | Y05 |
D. Do the operational test of the instrument and panel integral lighting (Ref. AMM TASK 33-13-00-710-001).
5. Close-upSubtask 33-13-44-942-050-A
A. Make sure that the work area is clean and clear of tools and other items.
Integrally-Lighted Identification Plate