Installation of the Accumulator Pressure Gage
TASK 32-44-14-400-001-A
Installation of the Accumulator Pressure Gage
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Referenced Information
3. Job Set-up
Subtask 32-44-14-860-051-A
Subtask 32-44-14-420-050-A
Subtask 32-44-14-410-050-A
[Rev.10 from 2021]
2026.04.01 07:51:17 UTC
Installation of the Accumulator Pressure Gage
WARNING:
MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
OBEY THE HYDRAULIC SAFETY PROCEDURES.
FIN: 2585GM
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | WARNING NOTICE(S) |
| No specific | Torque wrench: range to between 1.65 and 1.54 m.daN (12.17 and 11.36 lbf.ft ) ![]() |
| REFERENCE | DESIGNATION |
|---|---|
| No specific | corrosion-resistant steel lockwire 0.8 mm (0.032 in.) dia. |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-14-32-614-002-A | Nitrogen Filling of the Yellow Hydraulic System, Brake Pressure Accumulator |
| TASK 29-10-00-864-002-A | Depressurize the Yellow Hydraulic System |
| TASK 29-23-00-860-001-A | Disconnection of the Isolation Coupling of the Power Transfer Unit (PTU) |
| TASK 29-23-00-860-002-A | Connection of the Isolation Coupling of the Power Transfer Unit (PTU) |
| TASK 32-12-00-410-001-A | Close the Main Gear Doors after Access |
Subtask 32-44-14-860-051-A
A. Aircraft Maintenance Configuration
(1) Make sure that the PTU isolation coupling is disconnected (Ref. AMM TASK 29-23-00-860-001).
(2) Make sure that the Yellow hydraulic system is depressurized (Ref. AMM TASK 29-10-00-864-002).
Subtask 32-44-14-865-051-A (1) Make sure that the PTU isolation coupling is disconnected (Ref. AMM TASK 29-23-00-860-001).
(2) Make sure that the Yellow hydraulic system is depressurized (Ref. AMM TASK 29-10-00-864-002).
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
Subtask 32-44-14-941-051-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | L/G/Y BRK/PRESS/IND | 61GG | C10 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | ABCU &/Y BRK/PRESS IND | 61GG | C10 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/HYD POWER/Y | 3803GX | N30 |
| ** ON A/C ALL | |||
| 121VU | HYDRAULIC/BRAKING AND STEERING/SYS2/SPLY | 4GG | M36 |
| 121VU | HYDRAULIC/BRAKING AND STEERING/SYS2/CTL | 3GG | M35 |
| 121VU | HYDRAULIC/BRAKING AND STEERING/SYS1/CTL | 1GG | M34 |
| 121VU | HYDRAULIC/BRAKING AND STEERING/SYS1/IND AND/SPLY | 2GG | M33 |
| 121VU | HYDRAULIC/PARK BRK/CTL/STBY | 71GG | N37 |
| 121VU | HYDRAULIC/PARK BRK/CTL/NORM | 70GG | N36 |
| 121VU | HYDRAULIC/Y HYD/PUMP ENG2/MONG | 3700GD | Q37 |
| 121VU | HYDRAULIC/Y HYD/PUMP ENG2/CTL | 3701GD | Q36 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/HYD POWER/Y | 3803GX | N31 |
| ** ON A/C ALL | |||
| 123VU | Y HYD/ELEC/PUMP | 3802GX | AB06 |
| 123VU | Y HYD/ELEC/ELEC PUMP/NORM | 3801GX | AB03 |
C. Safety Precautions
(1) Make sure that the WARNING NOTICE(S) are in position to tell persons not to pressurize the Yellow hydraulic system:
Subtask 32-44-14-560-050-A (1) Make sure that the WARNING NOTICE(S) are in position to tell persons not to pressurize the Yellow hydraulic system:
- on the panel 40VU in the cockpit,
- on the ground service panel of the Yellow hydraulic system.
D. Preparation for Installation
(1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Make sure that the parts retained from the removed component are clean and in the correct condition.
4. Procedure(1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Make sure that the parts retained from the removed component are clean and in the correct condition.
Subtask 32-44-14-420-050-A
A. Installation of the Accumulator Pressure Gage 2585GM
(1) Remove the blanking plugs.
(2) Install the gage (6) on the adapter (4).
(3) TORQUE the nut (5) to between 1.65 and 1.54 m.daN (12.17 and 11.36 lbf.ft )
.
(5) Connect the PTU isolation coupling (Ref. AMM TASK 29-23-00-860-002).
Subtask 32-44-14-614-050-A Subtask 32-44-14-210-051-A (1) Remove the blanking plugs.
(2) Install the gage (6) on the adapter (4).
(3) TORQUE the nut (5) to between 1.65 and 1.54 m.daN (12.17 and 11.36 lbf.ft )
. WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(4) Safety the nut (5) with corrosion-resistant steel lockwire 0.8 mm (0.032 in.) dia.(5) Connect the PTU isolation coupling (Ref. AMM TASK 29-23-00-860-002).
C. Visual Inspection
(1) Make sure that there are no leaks.
(2) Make sure that the pressure in the accumulator is stable.
(3) Make sure that the cap (2) is installed on the charging valve (3).
Subtask 32-44-14-865-052-A (1) Make sure that there are no leaks.
(2) Make sure that the pressure in the accumulator is stable.
(3) Make sure that the cap (2) is installed on the charging valve (3).
D. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
5. Close-up| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | L/G/Y BRK/PRESS/IND | 61GG | C10 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | ABCU &/Y BRK/PRESS IND | 61GG | C10 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/HYD POWER/Y | 3803GX | N30 |
| ** ON A/C ALL | |||
| 121VU | HYDRAULIC/BRAKING AND STEERING/SYS2/SPLY | 4GG | M36 |
| 121VU | HYDRAULIC/BRAKING AND STEERING/SYS2/CTL | 3GG | M35 |
| 121VU | HYDRAULIC/BRAKING AND STEERING/SYS1/CTL | 1GG | M34 |
| 121VU | HYDRAULIC/BRAKING AND STEERING/SYS1/IND AND/SPLY | 2GG | M33 |
| 121VU | HYDRAULIC/PARK BRK/CTL/STBY | 71GG | N37 |
| 121VU | HYDRAULIC/PARK BRK/CTL/NORM | 70GG | N36 |
| 121VU | HYDRAULIC/Y HYD/PUMP ENG2/MONG | 3700GD | Q37 |
| 121VU | HYDRAULIC/Y HYD/PUMP ENG2/CTL | 3701GD | Q36 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/HYD POWER/Y | 3803GX | N31 |
| ** ON A/C ALL | |||
| 123VU | Y HYD/ELEC/PUMP | 3802GX | AB06 |
| 123VU | Y HYD/ELEC/ELEC PUMP/NORM | 3801GX | AB03 |
Subtask 32-44-14-410-050-A
A. Close Access
(1) Remove the WARNING NOTICE(S).
(2) Remove the access platform(s).
(3) Make sure that the work area is clean and clear of tools and other items.
(4) Close the right MLG door (Ref. AMM TASK 32-12-00-410-001).
(5) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Remove the WARNING NOTICE(S).
(2) Remove the access platform(s).
(3) Make sure that the work area is clean and clear of tools and other items.
(4) Close the right MLG door (Ref. AMM TASK 32-12-00-410-001).
(5) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Accumulator Pressure Gage 2585GM