W DOC AIRBUS | AMM A320F

Removal of the Temperature Sensor


TASK 30-73-17-000-003-A
Removal of the Temperature Sensor


ZONE: 131
FIN: 10DW ** ON A/C NOT FOR ALL
FIN: 300DW ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT)
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
131
FORWARD CARGO COMPARTMENT
825
FOR [10DW] (SENSOR,TEMPERATURE-)
131HW
FOR [300DW] (SENSOR,TEMPERATURE-)
131PW, 131RW
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
3. Job Set-up
Subtask 30-73-17-861-052-A ** ON A/C NOT FOR ALL
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 30-73-17-865-056-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2000VUPOT WIP-HEATER-LINE1DWA02
2000VUPOT WIP-HEATER-CTL2DWA01
Subtask 30-73-17-010-054-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Put the ACCESS PLATFORM 2M (6 FT) in position at the FWD cargo-compartment door 825.
   (2) Open the FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
   (3) Set the CARGO COMPT LIGHT switch 6LU to ON.
   (4) In the FWD cargo-compartment, remove the panels:
     (a) FOR [10DW] (SENSOR,TEMPERATURE-)
131HW
     (b) FOR [300DW] (SENSOR,TEMPERATURE-)
131RW 131PW
4. Procedure
Subtask 30-73-17-020-052-A ** ON A/C NOT FOR ALL
A. Removal of the Sensor
   (1) Remove the velcro tape (6) that attaches the sleeve (5) around the sensor.
   (2) Remove the sleeve (5) from around the clamp sensor assembly (1) and the clamp (2).
   (3) Disconnect the two wires of the clamp sensor assembly (1) from the terminal block.
   (4) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (5) On the potable water pipe, remove the screws (3) and (4) from the clamp sensor assembly (1) and the clamp (2).
   (6) Remove the clamp (2).
   (7) Remove the clamp sensor assembly (1).
[Rev.10 from 2021] 2026.04.01 08:24:54 UTC