Removal of the Waste-Water De-icing Heater Elements
TASK 30-71-53-000-003-A
Removal of the Waste-Water De-icing Heater Elements
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 30-71-53-861-052-A ** ON A/C NOT FOR ALL Subtask 30-71-53-010-055-A ** ON A/C NOT FOR ALL
Subtask 30-71-53-020-053-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 06:17:37 UTC
Removal of the Waste-Water De-icing Heater Elements
ZONE: 127
FIN: 142DU ** ON A/C NOT FOR ALL
FIN: 146DU ** ON A/C NOT FOR ALL
FIN: 147DU ** ON A/C NOT FOR ALL
1. Reason for the JobFIN: 142DU ** ON A/C NOT FOR ALL
FIN: 146DU ** ON A/C NOT FOR ALL
FIN: 147DU ** ON A/C NOT FOR ALL
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 127 | REAR AVIONIC COMPARTMENT |
| 825 | |
| FOR [142DU] (HEATER-TAPE, WASTE WTR) | |
| 131GW | |
| FOR [146DU] (HEATER-TAPE,) | |
| 131GW, 131HW | |
| FOR [147DU] (HEATER-TAPE,) | |
| 131HW, 131MW | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 30-71-17-000-003-A | Removal of the Temperature Sensor |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 30-71-53-861-052-A ** ON A/C NOT FOR ALL Subtask 30-71-53-010-055-A ** ON A/C NOT FOR ALL
B. Get Access
(1) Put an ACCESS PLATFORM 2M (6 FT) in position at the FWD cargo-compartment door 825.
(2) Open the FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
(3) Set the CARGO COMPT LIGHT switch 6LU to ON position.
(4) In the FWD cargo-compartment, remove the panels:
(a) FOR [142DU] (HEATER-TAPE, WASTE WTR)
131GW
(b) FOR [146DU] (HEATER-TAPE,)
131GW 131HW
(c) FOR [147DU] (HEATER-TAPE,)
131HW 131MW
Subtask 30-71-53-865-056-A ** ON A/C NOT FOR ALL (1) Put an ACCESS PLATFORM 2M (6 FT) in position at the FWD cargo-compartment door 825.
(2) Open the FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
(3) Set the CARGO COMPT LIGHT switch 6LU to ON position.
(4) In the FWD cargo-compartment, remove the panels:
(a) FOR [142DU] (HEATER-TAPE, WASTE WTR)
131GW
(b) FOR [146DU] (HEATER-TAPE,)
131GW 131HW
(c) FOR [147DU] (HEATER-TAPE,)
131HW 131MW
C. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | POT WIP-HEATER-LINE | 1DW | A02 |
| 2000VU | POT WIP-HEATER-CTL | 2DW | A01 |
Subtask 30-71-53-020-053-A ** ON A/C NOT FOR ALL
A. Removal of the Heater Element
(1) Remove and discard the cable ties (2) of the identification and warning labels (1).
(2) Remove the clamps (11) and the spacers (10).
(3) Remove the velcro tape (3), the adhesive tape (9) and the insulation muffs (4).
(4) Carefully remove and discard the adhesive tape (7) which is on the longitudinal cut of the insulation sleeve (8).
(5) Remove the insulation sleeve (8).
(6) Disconnect the three wires of the heater element (5) from the terminal block.
(8) Remove and discard the heat-shrink sleeve that safeties both ends of the glass fiber tape (6).
(10) Remove the heater element (5).
(1) Remove and discard the cable ties (2) of the identification and warning labels (1).
(2) Remove the clamps (11) and the spacers (10).
(3) Remove the velcro tape (3), the adhesive tape (9) and the insulation muffs (4).
(4) Carefully remove and discard the adhesive tape (7) which is on the longitudinal cut of the insulation sleeve (8).
(5) Remove the insulation sleeve (8).
(6) Disconnect the three wires of the heater element (5) from the terminal block.
NOTE: Identify all the electrical wires before you disconnect them.
(7) If necessary, remove the related temperature sensor (Ref. AMM TASK 30-71-17-000-003). (8) Remove and discard the heat-shrink sleeve that safeties both ends of the glass fiber tape (6).
NOTE: Do not damage the waste water line when you remove the heat-shrink sleeve.
(9) Remove and discard the glass fiber tape (6) that attaches the heater element (5). (10) Remove the heater element (5).
Heater Element