Reactivation of the Reservoir Air Pressure Switch of the Blue Hydraulic System
FIN: 2384GH
1. Reason for the JobMMEL 29-09-04A
HYD G(B)(Y) RSVR LO AIR PR ALERT
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 197FB |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 29-14-00-614-002-A | Pressurization of the Hydraulic Reservoirs through the Ground Connector |
| TASK 29-14-00-614-002-A-01 | Pressurization of the Hydraulic Reservoirs with the Auxiliary Power Unit (APU) |
Subtask 29-34-00-865-066-A
A. Open, safety and tag this(these) circuit breaker(s):
Subtask 29-34-00-010-054-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | HYD/HYD PWR/B WARN/& CTL | 2702GJ | C12 |
B. Get Access
(1) Open the access door 197FB.
(2) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position to be satisfactory for the Blue reservoir.
4. Procedure(1) Open the access door 197FB.
(2) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position to be satisfactory for the Blue reservoir.
Subtask 29-34-00-440-051-A
A. Reactivation of the Reservoir Air Pressure-Switch
(1) Cut and discard the tie-wrap which attaches the cable of the pressure switch 2384GH to the structure.
(2) Remove the protective caps from the connector (1) and the receptacle.
(3) Make sure that all the electrical connections are clean and in the correct condition.
(4) Connect the electrical connector (1) 2384GH-A to the pressure switch.
(5) Do the troubleshooting of the air pressure indication-system and do the applicable corrective procedure.
(6) Make sure that the reservoir is pressurized with air to the correct pressure (Ref. AMM TASK 29-14-00-614-002).
5. Close-up(1) Cut and discard the tie-wrap which attaches the cable of the pressure switch 2384GH to the structure.
(2) Remove the protective caps from the connector (1) and the receptacle.
(3) Make sure that all the electrical connections are clean and in the correct condition.
(4) Connect the electrical connector (1) 2384GH-A to the pressure switch.
(5) Do the troubleshooting of the air pressure indication-system and do the applicable corrective procedure.
(6) Make sure that the reservoir is pressurized with air to the correct pressure (Ref. AMM TASK 29-14-00-614-002).
Subtask 29-34-00-410-054-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 197FB.
(3) Remove the warning notice from the flight compartment.
Subtask 29-34-00-865-069-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 197FB.
(3) Remove the warning notice from the flight compartment.
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | HYD/HYD PWR/B WARN/& CTL | 2702GJ | C12 |
Reservoir Air Pressure Switch of the Blue Hydraulic System