Deactivation of the Reservoir Air Pressure Switch and Check of the Reservoir Air Pressure of the Blue Hydraulic System


TASK 29-34-00-040-002-A
Deactivation of the Reservoir Air Pressure Switch and Check of the Reservoir Air Pressure of the Blue Hydraulic System


FIN: 2384GH
Task Summary
Access Test Specific Tools Mhr E/T Nb Men
YESNONO0.30.31
1. Reason for the Job
MMEL 29-09-04A
HYD G(B)(Y) RSVR LO AIR PR ALERT
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
2
CAP - PROTECTION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
TIE WRAP(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
197FB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 29-14-00-614-002-A
Pressurization of the Hydraulic Reservoirs through the Ground Connector
TASK 29-14-00-614-002-A-01
Pressurization of the Hydraulic Reservoirs with the Auxiliary Power Unit (APU)
3. Job Set-up
Subtask 29-34-00-865-064-A
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUHYD/HYD PWR/B WARN/& CTL2702GJC12
Subtask 29-34-00-010-053-A
B. Get Access
   (1) Open the access door 197FB.
   (2) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position to be satisfactory for the Blue reservoir.
4. Procedure
Subtask 29-34-00-040-051-A
A. Deactivation of the Reservoir Air Pressure Switch
   (1) Disconnect the electrical connector (1) 2384GH-A from the pressure switch.
   (2) Install a CAP - PROTECTION on the disconnected connector (1) and on the receptacle.
   (3) Use a TIE WRAP(S) and attach the disconnected cable to a part of the structure.
NOTE: Attach the cable to the structure so that the disconnected end of the connector points down. This prevents the contamination of the connector with oil or other liquids.
   (4) Make an entry in the logbook.
   (5) Look on the air pressure gages of the reservoir and make sure that the air pressure is not less than 37 psi.
   (6) If necessary, pressurize the reservoir (Ref. AMM TASK 29-14-00-614-002).
5. Close-up
Subtask 29-34-00-410-053-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the access platform.
   (3) Close the access door 197FB.
Subtask 29-34-00-865-068-A
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUHYD/HYD PWR/B WARN/& CTL2702GJC12