W DOC AIRBUS | AMM A320F

Deactivation of the Reservoir Air Pressure Switches and Check of the Reservoir Air Pressure of the Green and Yellow Hydraulic System


TASK 29-34-00-040-001-A
Deactivation of the Reservoir Air Pressure Switches and Check of the Reservoir Air Pressure of the Green and Yellow Hydraulic System


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
FIN: 1384GH
FIN: 3384GH
Task Summary
Access Test Specific Tools Mhr E/T Nb Men
YESYESNO0.30.31
1. Reason for the Job
MMEL 29-09-04A
HYD G(B)(Y) RSVR LO AIR PR ALERT
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
2
CAP - PROTECTION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
TIE WRAP(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
196BB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 29-14-00-614-002-A
Pressurization of the Hydraulic Reservoirs through the Ground Connector
TASK 29-14-00-614-002-A-01
Pressurization of the Hydraulic Reservoirs with the Auxiliary Power Unit (APU)
TASK 32-12-00-010-001-A
Open the Main Gear Doors for Access
TASK 32-12-00-410-001-A
Close the Main Gear Doors after Access
3. Job Set-up
Subtask 29-34-00-865-050-A
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 1384GH (AIR PRESSURE SWITCH)
121VUHYDRAULIC/G HYD/PUMP ENG1/MONG1702GKR34
** ON A/C NOT FOR ALL
121VUHYDRAULIC/G HYD/PUMP ENG1/MONG1702GKR33
** ON A/C ALL
FOR FIN: 3384GH (AIR PRESSURE SWITCH)
121VUHYDRAULIC/Y HYD/PUMP ENG2/MONG3700GDQ37
Subtask 29-34-00-010-050-A
B. Get Access
   (1) Open the applicable access door:
NOTE: Access is better from the Right Hand (RH) side.
   (2) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position to be satisfactory for the Green reservoir.
4. Procedure
Subtask 29-34-00-040-050-A
A. Deactivation of the Reservoir Air Pressure Switches
   (1) Disconnect the applicable electrical connector (1) 1384GH-A or 3384GH-A from the pressure switch.
   (2) Install a CAP - PROTECTION on the disconnected connector (1) and on the receptacle.
   (3) For the pressure switch 1384GH:
  • Use a TIE WRAP(S) and attach the disconnected cable to a part of the structure.
NOTE: Attach the cable to the structure so that the disconnected end of the connector points down. This prevents the contamination of the connector with oil or other liquids.
   (4) For the pressure switch 3384GH:
     (a) Put the disconnected connector and the end of the cable through the hole in FR42 into the main gear compartment.
     (b) Use a TIE WRAP(S) and attach the disconnected cable to a part of the structure in the main gear compartment.
NOTE: Attach the cable to the structure so that the disconnected end of the connector points down. This prevents the contamination of the connector with oil or other liquids.
   (5) Make an entry in the logbook.
   (6) Look on the air pressure gages on the applicable reservoir and make sure that the air pressure is not less than 37 psi.
   (7) If necessary, pressurize the reservoir (Ref. AMM TASK 29-14-00-614-002).
5. Close-up
Subtask 29-34-00-410-050-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the access platform.
   (3) Close the applicable access door(s)
Subtask 29-34-00-865-070-A
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 1384GH (AIR PRESSURE SWITCH)
121VUHYDRAULIC/G HYD/PUMP ENG1/MONG1702GKR34
** ON A/C NOT FOR ALL
121VUHYDRAULIC/G HYD/PUMP ENG1/MONG1702GKR33
** ON A/C ALL
FOR FIN: 3384GH (AIR PRESSURE SWITCH)
121VUHYDRAULIC/Y HYD/PUMP ENG2/MONG3700GDQ37
[Rev.10 from 2021] 2026.04.01 00:28:00 UTC