Visual Check of NACA Intake for Signs of Blockage
TASK 28-12-47-200-001-A
Visual Check of NACA Intake for Signs of Blockage
Refer to the MPD TASK: 281247-01
VISUAL CHECK OF NACA INTAKE FOR SIGNS OF BLOCKAGE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 28-12-47-941-052-A
Subtask 28-12-47-210-053-A
Subtask 28-12-47-942-051-A
[Rev.10 from 2021]
2026.04.01 04:08:58 UTC
Visual Check of NACA Intake for Signs of Blockage
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
1. Reason for the Job- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
Refer to the MPD TASK: 281247-01
VISUAL CHECK OF NACA INTAKE FOR SIGNS OF BLOCKAGE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 4M (13 FT) |
| No specific | AR | SAFETY BARRIER(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 550 | VENT SURGE TANK |
| 650 | VENT SURGE TANK |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 28-00-00-910-001-A | Fuel Safety Procedures |
| TASK 28-12-47-000-001-A | Removal of the NACA Vent Intake (for corrective action) |
| TASK 28-12-47-400-001-A | Installation of the NACA Vent Intake (for corrective action) |
Subtask 28-12-47-941-052-A
A. Safety Precautions
(2) Put the SAFETY BARRIER(S) in position.
Subtask 28-12-47-010-052-A WARNING:
OBEY THE FUEL SAFETY PROCEDURES.
(1) You must obey the fuel safety procedures when you do work on the fuel system (Ref. AMM TASK 28-00-00-910-001). (2) Put the SAFETY BARRIER(S) in position.
B. Get Access
(1) Put the ACCESS PLATFORM 4M (13 FT) below the applicable access panel 550AB(650AB).
4. Procedure(1) Put the ACCESS PLATFORM 4M (13 FT) below the applicable access panel 550AB(650AB).
Subtask 28-12-47-210-053-A
A. Visual Check of the NACA Intake for Signs of Blockage
(1) Examine the NACA vent door 550AB (650AB) for signs of leaks and damage.
5. Close-up(1) Examine the NACA vent door 550AB (650AB) for signs of leaks and damage.
NOTE: (Ref. AMM TASK 28-12-47-000-001) (Ref. AMM TASK 28-12-47-400-001) for corrective action.
(2) Examine the NACA vent intake for contamination and make sure that there is no blockage. If necessary remove the contamination and/or the blockage. Subtask 28-12-47-942-051-A
A. Removal of Equipment
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the safety barriers.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
(5) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the safety barriers.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
(5) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
NACA Vent Intake