W DOC AIRBUS | AMM A320F

Read-out for Class 3 Faults in the Slat System


TASK 27-81-00-740-001-A
Read-out for Class 3 Faults in the Slat System


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
WARNING NOTICE(S)
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 31-32-00-869-002-A
Procedure for the Class 3 Fault Reading
3. Job Set-up
Subtask 27-81-00-941-054-A
A. Safety Precautions
   (1) Put a WARNING NOTICE(S) in position to tell persons not to operate the slats.
4. Procedure
Subtask 27-81-00-869-051-A
A. Read-out for Class 3 Faults in the Slat System
WARNING: MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
   (1) Read for class 3 faults in the slat system (Ref. AMM TASK 31-32-00-869-002).
5. Close-up
Subtask 27-81-00-942-054-A
A. Removal of Equipment
   (1) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.03.31 23:56:20 UTC