Removal of the Position Transducer from the THS Actuator
TASK 27-44-56-000-001-A
Removal of the Position Transducer from the THS Actuator
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 27-44-56-010-050-A
Subtask 27-44-56-020-050-A
[Rev.10 from 2021]
2026.04.01 06:54:32 UTC
Removal of the Position Transducer from the THS Actuator
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| 0U190360 | 1 | PIN-RIGGING,THS ACTUATOR,MECHANICAL INPUT LEVER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 310 | FUSLG TAIL SECTION AFT OF AFT PRESS BHD |
| 312AR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 29-00-00-864-001-A | Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action |
Subtask 27-44-56-010-050-A
A. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position.
(2) Open the access door 312AR.
Subtask 27-44-56-860-051-A (1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position.
(2) Open the access door 312AR.
B. Aircraft Maintenance Configuration
(1) Turn the pitch-trim control wheel in the cockpit and put the THS actuator (1) near to the zero position.
(2) Put the 0U190360 PIN-RIGGING,THS ACTUATOR,MECHANICAL INPUT LEVER in the mechanical input of the THS actuator (1).
(3) Put the WARNING NOTICE(S) in the cockpit to tell persons not to operate the pitch controls.
Subtask 27-44-56-865-050-A (1) Turn the pitch-trim control wheel in the cockpit and put the THS actuator (1) near to the zero position.
(2) Put the 0U190360 PIN-RIGGING,THS ACTUATOR,MECHANICAL INPUT LEVER in the mechanical input of the THS actuator (1).
(3) Put the WARNING NOTICE(S) in the cockpit to tell persons not to operate the pitch controls.
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 27-44-56-860-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/ELAC1/NORM/SPLY | 15CE1 | B11 |
| 49VU | FLIGHT CONTROLS/THS/ACTR/MOT2 | 19CE2 | B09 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/ELAC1/NORM/SPLY | 15CE1 | B06 |
| 49VU | FLIGHT CONTROLS/THS/ACTR/MOT2 | 19CE2 | B04 |
| ** ON A/C ALL | |||
| 105VU | FLT CTL/ELAC1/STBY SPLY | 16CE1 | A01 |
| 121VU | FLIGHT CONTROLS/THS ACTR/MOT3 | 19CE3 | Q17 |
| 121VU | FLIGHT CONTROLS/THS ACTR/MOT1 | 19CE1 | Q16 |
D. Aircraft Maintenance Configuration
(1) Make sure that the Green and the Yellow hydraulic systems are depressurized and put them in the maintenance configuration (Ref. AMM TASK 29-00-00-864-001).
(2) Put the WARNING NOTICE(S) in position to tell persons not to pressurize the Green and the Yellow hydraulic systems.
4. Procedure(1) Make sure that the Green and the Yellow hydraulic systems are depressurized and put them in the maintenance configuration (Ref. AMM TASK 29-00-00-864-001).
(2) Put the WARNING NOTICE(S) in position to tell persons not to pressurize the Green and the Yellow hydraulic systems.
Subtask 27-44-56-020-050-A
A. Removal of the Position Transducer
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Hold the position transducer (2) and remove the screws (7) and the washers (8).
(4) Remove the position transducer (2) from the THS actuator (1).
NOTE: The removal of the Command Position Transducer (COM) and the Monitor Position Transducer (MON) is the same. The removal procedure for one of the position transducers only is given.
(1) Disconnect the electrical connectors (3),(4) from the receptacles (5),(6). (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Hold the position transducer (2) and remove the screws (7) and the washers (8).
(4) Remove the position transducer (2) from the THS actuator (1).
Position Transducer