Removal of the Electrical Load Sensing Device
TASK 27-44-51-000-802-A
Removal of the Electrical Load Sensing Device
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 27-44-51-010-068-A ** ON A/C NOT FOR ALL
Subtask 27-44-51-020-055-A
[Rev.10 from 2021]
2026.04.01 06:54:07 UTC
Removal of the Electrical Load Sensing Device
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
ZONE: 310
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| 98D27403500000 | 1 | PITCH TRIM CONTROL LOCKING |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 310 | FUSLG TAIL SECTION AFT OF AFT PRESS BHD |
| 312AR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 29-00-00-864-001-A | Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action |
Subtask 27-44-51-010-068-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position.
(2) Open the access door 312AR.
Subtask 27-44-51-860-071-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position.
(2) Open the access door 312AR.
B. Aircraft Maintenance Configuration
(Ref. AMM TASK 29-00-00-864-001).
(2) Put the WARNING NOTICE(S) in position to tell persons not to pressurize the Green, the Yellow and the Blue hydraulic systems:
(4) Put the 98D27403500000 PITCH TRIM CONTROL LOCKING on the pitch-trim control wheel in the flight compartment.
Subtask 27-44-51-865-071-A ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Make sure that the hydraulic systems are depressurized and put them in the maintenance configuration(Ref. AMM TASK 29-00-00-864-001).
(2) Put the WARNING NOTICE(S) in position to tell persons not to pressurize the Green, the Yellow and the Blue hydraulic systems:
- in the cockpit on the hydraulic section 40VU of the overhead panel,
- on the ground service panels of the Green, the Yellow and the Blue hydraulic systems.
(4) Put the 98D27403500000 PITCH TRIM CONTROL LOCKING on the pitch-trim control wheel in the flight compartment.
C. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/ELAC1/NORM/SPLY | 15CE1 | B11 |
| 49VU | FLIGHT CONTROLS/THS/ACTR/MOT2 | 19CE2 | B09 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/ELAC1/NORM/SPLY | 15CE1 | B06 |
| 49VU | FLIGHT CONTROLS/THS/ACTR/MOT2 | 19CE2 | B04 |
| ** ON A/C ALL | |||
| 105VU | FLT CTL/ELAC1/STBY SPLY | 16CE1 | A01 |
| 121VU | FLIGHT CONTROLS/THS ACTR/MOT3 | 19CE3 | Q17 |
| 121VU | FLIGHT CONTROLS/THS ACTR/MOT1 | 19CE1 | Q16 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | THS ACTR/ELSD | 95CE | Q15 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | THS ACTR/ELSD | 95CE | P15 |
Subtask 27-44-51-020-055-A
A. Removal of the Electrical Load Sensing Device (ELSD)
(1) Remove the bonding strap (10):
(a) Remove the nut (13), the washer (12), the bolt (9), the lanyard of the protective cap EN3645-F3B0 (8) and the bonding strap (10) from the ELSD (11).
(2) Remove the ELSD (11):
(a) Remove the nuts (2), the locking washers (3) and the springboxes (4) from the axes of the ELSD (11).
(b) Discard the locking washers (3).
(3) Remove the ELSD (11) and the bushes (14) from the secondary upper attachment (5) and the structure lug (1).
Subtask 27-44-51-020-055-B ** ON A/C NOT FOR ALL (1) Remove the bonding strap (10):
(a) Remove the nut (13), the washer (12), the bolt (9), the lanyard of the protective cap EN3645-F3B0 (8) and the bonding strap (10) from the ELSD (11).
(2) Remove the ELSD (11):
(a) Remove the nuts (2), the locking washers (3) and the springboxes (4) from the axes of the ELSD (11).
(b) Discard the locking washers (3).
(3) Remove the ELSD (11) and the bushes (14) from the secondary upper attachment (5) and the structure lug (1).
A. Removal of the Electrical Load Sensing Device (ELSD)
(1) Disconnect the electrical connector (8):
(a) Disconnect the electrical connector (8) from the ELSD (11).
(b) Put the CAP - BLANKING on each disconnected electrical connector and receptacle.
(2) Remove the bonding strap (10):
(a) Remove the nut (13), the washer (12), the bolt (9) and the bonding strap (10) from the ELSD (11).
(3) Remove the ELSD (11):
(a) Remove the nuts (2), the locking washers (3) and the springboxes (4) from the axes of the ELSD (11).
1 Discard the locking washers (3).
(b) Remove the ELSD (11) and the bushes (14) from the secondary upper attachment (5) and the structure lug (1).
(1) Disconnect the electrical connector (8):
(a) Disconnect the electrical connector (8) from the ELSD (11).
(b) Put the CAP - BLANKING on each disconnected electrical connector and receptacle.
(2) Remove the bonding strap (10):
(a) Remove the nut (13), the washer (12), the bolt (9) and the bonding strap (10) from the ELSD (11).
(3) Remove the ELSD (11):
(a) Remove the nuts (2), the locking washers (3) and the springboxes (4) from the axes of the ELSD (11).
1 Discard the locking washers (3).
(b) Remove the ELSD (11) and the bushes (14) from the secondary upper attachment (5) and the structure lug (1).
Electrical Load Sensing Device (ELSD)