Visual Inspection and Lubrication of the Rear THS control cable (between FR71 and the THS actuator)
TASK 27-41-00-210-003-A
Visual Inspection and Lubrication of the Rear THS control cable (between FR71 and the THS actuator)
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 27-41-00-010-062-A
Subtask 27-41-00-020-053-A
Subtask 27-41-00-410-058-A
[Rev.10 from 2021]
2026.03.31 23:50:52 UTC
Visual Inspection and Lubrication of the Rear THS control cable (between FR71 and the THS actuator)
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
ZONE: 310
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 310 | FUSLG TAIL SECTION AFT OF AFT PRESS BHD |
| 312AR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 20-24-11-100-001-A | Cleaning and Protection of the Cables |
| TASK 20-24-12-200-001-A | Check of the Control Cables |
Subtask 27-41-00-010-062-A
A. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the zone 312.
(2) Open the access door 312AR.
4. Procedure(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the zone 312.
(2) Open the access door 312AR.
Subtask 27-41-00-020-053-A
A. Removal of the Protective Covers
(1) Remove the screws (4) and the washers (3).
(2) Release the fasteners (1) and remove the protective covers (2) and (5).
Subtask 27-41-00-210-057-A (1) Remove the screws (4) and the washers (3).
(2) Release the fasteners (1) and remove the protective covers (2) and (5).
B. Visual Inspection of the Rear THS Control Cable
(1) Do an inspection the THS control cable between the tension regulator and the chain linkage.
(2) Make sure that the chain and the cable move freely.
(3) Make sure that the chain and the cable do not touch the structure (no marks on the fasteners).
(4) Make sure that the chain that controls the THS actuator is in the correct condition.
(5) Make sure that the cables are not damaged (Ref. AMM TASK 20-24-12-200-001).
(6) Clean and apply corrosion preventive compound on the cables (Ref. AMM TASK 20-24-11-100-001).
Subtask 27-41-00-420-051-A (1) Do an inspection the THS control cable between the tension regulator and the chain linkage.
(2) Make sure that the chain and the cable move freely.
(3) Make sure that the chain and the cable do not touch the structure (no marks on the fasteners).
(4) Make sure that the chain that controls the THS actuator is in the correct condition.
(5) Make sure that the cables are not damaged (Ref. AMM TASK 20-24-12-200-001).
(6) Clean and apply corrosion preventive compound on the cables (Ref. AMM TASK 20-24-11-100-001).
C. Installation of the Protective Covers
(1) Install the protective covers (2) and (5).
(2) Tighten the fasteners (1).
(3) Install the washers (3) and the screws (4).
5. Close-up(1) Install the protective covers (2) and (5).
(2) Tighten the fasteners (1).
(3) Install the washers (3) and the screws (4).
Subtask 27-41-00-410-058-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 312AR.
(3) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 312AR.
(3) Remove the access platform(s).
Removal/Installation of the Protective Covers