Check of the Position of the Reference Triangle on the Tail Cone
TASK 27-34-00-220-003-A
Check of the Position of the Reference Triangle on the Tail Cone
To do a check of the position of the reference triangle on the tail cone.
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 27-34-00-860-075-B
Subtask 27-34-00-220-058-C
Subtask 27-34-00-410-065-B
[Rev.10 from 2021]
2026.03.31 23:50:14 UTC
Check of the Position of the Reference Triangle on the Tail Cone
ZONE: 334
1. Reason for the JobTo do a check of the position of the reference triangle on the tail cone.
NOTE: This task lets you know if the position of the reference triangle on the tail cone is approximately correct. To do an accurate check of the reference triangle position, it is necessary to use the Gauge-Elevator Neutral Setting tool and the procedure given in AMM task 273400-820-003.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 2 | ACCESS PLATFORM 6M (20 FT) - ADJUSTABLE |
| 98D27309002000 | 1 | GAUGE-ELEVATOR NEUTRAL SETTING |
| 98D27309006000 | 1 | GAUGE-ELEVATOR NEUTRAL SETTING |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 334 | THS TRAILING EDGE |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 27-34-00-820-003-B | Adjustment of the Elevator and Hydraulic Actuation to 0.5 Degrees Nose-Up with the Gauge-Elevator Neutral Setting (98D27309006000) |
| TASK 27-34-00-820-003-B-01 | Adjustment of the Elevator and Hydraulic Actuation to 0.5 Degrees Nose-Up with the Gauge-Elevator Neutral Setting (98D27309002000) |
Subtask 27-34-00-860-075-B
A. Aircraft Maintenance Configuration
(1) Put a warning notice in position in the cockpit to tell persons not to pressurize the hydraulic systems.
Subtask 27-34-00-010-067-B (1) Put a warning notice in position in the cockpit to tell persons not to pressurize the hydraulic systems.
B. Get Access
(1) Put the ACCESS PLATFORM 6M (20 FT) - ADJUSTABLE in position under the left elevator.
4. Procedure(1) Put the ACCESS PLATFORM 6M (20 FT) - ADJUSTABLE in position under the left elevator.
Subtask 27-34-00-220-058-C
A. Check of the Position of the Reference Triangle
(1) Make a mark at 780 mm (30.7087 in.) from the forward corner of the APU access door 315AL.
(2) From this mark, measure the distance along the skin between the edge of the stucture and the center of the triangle.
(4) Make a mark at 780 mm (30.7087 in.) from the forward corner of the APU access door 316AR.
(5) From this mark, measure the distance along the skin between the edge of the stucture and the center of the triangle.
5. Close-up(1) Make a mark at 780 mm (30.7087 in.) from the forward corner of the APU access door 315AL.
(2) From this mark, measure the distance along the skin between the edge of the stucture and the center of the triangle.
NOTE: The position of the triangle must be between 386 mm (15.1969 in.) and 402 mm (15.8268 in.).
(a) If the position of the triangle is not between these two values: - do not adjust the elevators with the reference triangle
- adjust the elevators with the 98D27309002000 GAUGE-ELEVATOR NEUTRAL SETTING or 98D27309006000 GAUGE-ELEVATOR NEUTRAL SETTING, (Ref. AMM TASK 27-34-00-820-003).
- the position of the triangle is correct; no maintenance action is necessary.
(4) Make a mark at 780 mm (30.7087 in.) from the forward corner of the APU access door 316AR.
(5) From this mark, measure the distance along the skin between the edge of the stucture and the center of the triangle.
NOTE: The position of the triangle must be between 386 mm (15.1969 in.) and 402 mm (15.8268 in.).
(a) If the position of the triangle is not between these two values: - do not adjust the elevators with the reference triangle
- adjust the elevators with the 98D27309002000 GAUGE-ELEVATOR NEUTRAL SETTING or 98D27309006000 GAUGE-ELEVATOR NEUTRAL SETTING, (Ref. AMM TASK 27-34-00-820-003).
- the position of the triangle is correct; no maintenance action is necessary.
Subtask 27-34-00-410-065-B
A. Close Access
(1) Remove the WARNING NOTICE(S).
(2) Remove the access platform(s).
(1) Remove the WARNING NOTICE(S).
(2) Remove the access platform(s).
Triangle Reference on the Tail Cone