Removal of the Pressure Reducer
TASK 26-23-18-000-001-A
Removal of the Pressure Reducer
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 26-23-18-861-051-A ** ON A/C NOT FOR ALL
Subtask 26-23-18-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:46:11 UTC
Removal of the Pressure Reducer
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | PLUG - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 130 | FWD CARGO COMPT AFT BULKHEAD OF AVNCS COMPT TO FWD PRESSURE BULKHEAD OF WING CENTER BOX |
| 132MW, 825 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 25-54-12-000-003-A | Removal of the Sidewall Panels in the Forward Cargo Compartment |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 26-23-18-861-051-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 26-23-18-865-052-A ** ON A/C NOT FOR ALL (1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 26-23-18-010-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/CARGO FIRE/EXTIG/BTL2 | 8WX | C05 |
| 49VU | AIR COND/CARGO/FIRE/EXTIG/BTL1 | 1WX | C04 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/CARGO FIRE/EXTIG/BTL2 | 8WX | C04 |
| 49VU | AIR COND/CARGO/FIRE/EXTIG/BTL1 | 1WX | C03 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/CARGO/FIRE/EXTIG | 1WX | T19 |
C. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below the forward cargo-compartment door 825.
(2) Open the forward cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
(3) Remove the protection panel 132MW (Ref. AMM TASK 25-54-12-000-003).
4. Procedure(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below the forward cargo-compartment door 825.
(2) Open the forward cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
(3) Remove the protection panel 132MW (Ref. AMM TASK 25-54-12-000-003).
Subtask 26-23-18-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Pressure Reducer
(2) Remove the unions (6).
(4) Release the tab washer (2) and remove the nut (1).
(5) Remove and discard the tab washer (2).
(6) Remove the pressure reducer (4).
(7) Put the PLUG-BLANKING in each disconnected line end.
(8) Put PLUG - BLANKING on the open ports of the pressure reducer (4).
NOTE: The removal procedure is the same for the pressure reducers 5014WM and 5015WM.
(1) Loosen the nuts (7) and disconnect the pipes (8). (2) Remove the unions (6).
NOTE: Retain the unions (6) for installation.
(3) Remove and discard the O-rings (5). (4) Release the tab washer (2) and remove the nut (1).
(5) Remove and discard the tab washer (2).
(6) Remove the pressure reducer (4).
(7) Put the PLUG-BLANKING in each disconnected line end.
(8) Put PLUG - BLANKING on the open ports of the pressure reducer (4).
Pressure Reducer (5014WM, 5015WM)