Removal of the APU Fire-Extinguisher Discharge-Outlet and Tubing
TASK 26-22-41-000-803-A
Removal of the APU Fire-Extinguisher Discharge-Outlet and Tubing
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 26-22-41-860-058-A
Subtask 26-22-41-020-058-A
[Rev.10 from 2021]
2026.03.31 23:45:39 UTC
Removal of the APU Fire-Extinguisher Discharge-Outlet and Tubing
WARNING:
BE VERY CAREFUL WHEN YOU MOVE A FULL FIRE EXTINGUISHER BOTTLE. A SUDDEN OR HEAVY SHOCK TO A FULL BOTTLE CAN CAUSE UNWANTED DISCHARGE AND INJURY TO PERSONS.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| No specific | AR | PLUG - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 314AR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 26-22-42-000-001-A | Removal of the Fire-Extinguisher Bottle Cartridge |
| TASK 52-41-23-010-801-A | Opening of Access Door 314AR |
Subtask 26-22-41-860-058-A
A. Put the WARNING NOTICE(S) on the overhead panel 25VU to tell the persons not to operate the APU.
Subtask 26-22-41-865-063-A B. Open, safety and tag this(these) circuit breaker(s):
Subtask 26-22-41-010-059-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | APU/FIRE AND OVHT/DET/LOOP B | 2WG | L44 |
| 121VU | APU/FIRE AND OVHT/DET/LOOP A | 1WG | L43 |
| 121VU | APU/APU/CTL | 2KD | L42 |
| 121VU | APU/ECB/SPLY | 1KD | L41 |
| 121VU | APU/FIRE/EXTIG/SQUIB/B | 2WF | L39 |
| 121VU | APU/FIRE/EXTIG/SQUIB/A | 1WF | L38 |
| 121VU | APU/FIRE/LP VALVE/NORM | 4WF | M42 |
| 121VU | APU/FIRE/LP VALVE/STBY | 3WF | M41 |
C. Get Access
(2) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below maintenance door 314AR.
(3) Open access door 314AR and safety it in the open position.
(Ref. AMM TASK 52-41-23-010-801).
(4) Set the light switch to on.
4. ProcedureWARNING:
BEFORE YOU START WORK, YOU MUST PUT ON A SAFETY HARNESS AND ATTACH IT TO THE ACCESS PLATFORM. WITHOUT A SAFETY HARNESS, YOU CAN FALL. THIS CAN KILL YOU OR CAUSE YOU INJURY.
(1) Put on and attach a safety harness before you start work in the work area(2) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below maintenance door 314AR.
(3) Open access door 314AR and safety it in the open position.
(Ref. AMM TASK 52-41-23-010-801).
(4) Set the light switch to on.
Subtask 26-22-41-020-058-A
A. Removal of the APU Fire-Extinguisher Discharge-Outlet (4015WM) and Tubing for Meggitt Assembly
(1) Remove the APU fire-extinguisher cartridge (Ref. AMM TASK 26-22-42-000-001).
(2) Removal of the spray tubing.
(b) Remove the clamp (5).
(c) Hold the spray tubing (6) in position, loosen the nuts (1) on the spray tubing (6) and slide them back.
(d) Remove the spray tubing (6).
(e) Remove and discard the O-rings (3) from the spray tubing (6).
(f) Remove the ring-retainings (2) from the spray tubing (6).
(g) Remove the bushing (4).
(3) Removal of the discharge outlet.
(b) Hold the discharge outlet (7) in position, loosen the swivel nut (8) completely and then remove the discharge outlet (7).
(c) Remove and discard the O-ring (9) from the discharge outlet (7).
(d) Put the PLUG-BLANKING in each disconnected line end.
Subtask 26-22-41-020-059-A (1) Remove the APU fire-extinguisher cartridge (Ref. AMM TASK 26-22-42-000-001).
(2) Removal of the spray tubing.
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(a) Remove and discard the lockwire from the couplings of the spray tubing (6). (b) Remove the clamp (5).
(c) Hold the spray tubing (6) in position, loosen the nuts (1) on the spray tubing (6) and slide them back.
(d) Remove the spray tubing (6).
(e) Remove and discard the O-rings (3) from the spray tubing (6).
(f) Remove the ring-retainings (2) from the spray tubing (6).
(g) Remove the bushing (4).
(3) Removal of the discharge outlet.
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(a) Remove and discard the lockwire from the discharge outlet (7). (b) Hold the discharge outlet (7) in position, loosen the swivel nut (8) completely and then remove the discharge outlet (7).
(c) Remove and discard the O-ring (9) from the discharge outlet (7).
(d) Put the PLUG-BLANKING in each disconnected line end.
B. Removal of the APU Fire-Extinguisher Discharge-Outlet (4015WM) and Tubing for Kidde Assembly
(1) Remove the APU fire-extinguisher cartridge (Ref. AMM TASK 26-22-42-000-001).
(2) Removal of the spray tubing.
(b) Remove the clamp (5).
(c) Hold the spray tubing (6) in position, loosen the nuts (1) on the spray tubing (6) and slide them back.
(d) Remove the spray tubing (6).
(e) Remove and discard the O-rings (3) from the spray tubing (6).
(f) Remove the ring-retainings (2) from the spray tubing (6).
(g) Remove the bushing (4).
(3) Removal of the discharge outlet.
(b) Hold the discharge outlet (7) in position, loosen the swivel nut (8) completely and then remove the discharge outlet (7).
(c) Put the PLUG-BLANKING in each disconnected line end.
(1) Remove the APU fire-extinguisher cartridge (Ref. AMM TASK 26-22-42-000-001).
(2) Removal of the spray tubing.
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(a) Remove and discard the lockwire from the couplings of the spray tubing (6). (b) Remove the clamp (5).
(c) Hold the spray tubing (6) in position, loosen the nuts (1) on the spray tubing (6) and slide them back.
(d) Remove the spray tubing (6).
(e) Remove and discard the O-rings (3) from the spray tubing (6).
(f) Remove the ring-retainings (2) from the spray tubing (6).
(g) Remove the bushing (4).
(3) Removal of the discharge outlet.
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(a) Remove and discard the lockwire from the discharge outlet (7). (b) Hold the discharge outlet (7) in position, loosen the swivel nut (8) completely and then remove the discharge outlet (7).
(c) Put the PLUG-BLANKING in each disconnected line end.
Extinguisher Discharge-Outlet and Tubing (Meggitt Bottle)