W DOC AIRBUS | AMM A320F

ENG FIRE TEST - Circuit Verification


TASK 26-21-00-040-002-A
ENG FIRE TEST - Circuit Verification


CAUTION: TO RESET THE ENG 1(2) APU FIRE PUSHBUTTON SWITCH:
  • PUSH THE PUSHBUTTON SWITCH FULLY IN (LATCHED POSITION).
THEN CLOSE THE GUARD. DO NOT TRY TO CLOSE THE GUARD AND PUSH THE PUSHBUTTON SWITCH AT THE SAME TIME.
ZONE: 210
ZONE: 415
ZONE: 425
FIN: 6WE1
FIN: 6WE2
FIN: 8WE1
FIN: 8WE2
Task Summary
Access Test Specific Tools Mhr E/T Nb Men
NOYESNO0.81.62
1. Reason for the Job
MMEL 26-01-01-31A
ENG FIRE TEST
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
415
LOWER PYLON
425
LOWER PYLON
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 26-12-00-710-002-A
Operational Test of the Engine Fire and Overheat Detection with the Centralized Fault Display System (CFDS)
TASK 26-12-00-710-002-B
Operational Test of the Engine Fire and Overheat Detection with the Centralized Fault Display System (CFDS)
TASK 26-21-00-040-003-A
Test of the Engine SQUIB Legend of the AGENT Pushbutton Switch
3. Job Set-up
Subtask 26-21-00-869-069-A
A. Not Applicable
4. Procedure
Subtask 26-21-00-710-056-A
A. Do an ENG FIRE TEST - Circuit Verification
   (1) Do the circuit verification of the ENG Agent SQUIB LTS
(Ref. AMM TASK 26-21-00-040-003).
   (2) Do the operational test from Multipurpose Control and Display Unit (MCDU)
(Ref. AMM TASK 26-12-00-710-002).
5. Close-up
Subtask 26-21-00-860-075-A
A. Put the aircraft back to its initial configuration.
   (1) Make an entry in the logbook.
[Rev.10 from 2021] 2026.03.31 23:44:28 UTC