Operational Test of the Engine Fire and Overheat Detection with the Centralized Fault Display System (CFDS)
TASK 26-12-00-710-002-B
Operational Test of the Engine Fire and Overheat Detection with the Centralized Fault Display System (CFDS)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 26-12-00-861-057-A ** ON A/C NOT FOR ALL Subtask 26-12-00-869-054-A ** ON A/C NOT FOR ALL
Subtask 26-12-00-710-054-A ** ON A/C NOT FOR ALL
Subtask 26-12-00-869-055-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:42:19 UTC
Operational Test of the Engine Fire and Overheat Detection with the Centralized Fault Display System (CFDS)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-32-00-860-005-A | Procedure to Get Access to the SYSTEM REPORT/TEST FIRE PROT Page |
Subtask 26-12-00-861-057-A ** ON A/C NOT FOR ALL Subtask 26-12-00-869-054-A ** ON A/C NOT FOR ALL
B. On the ENG panel 115VU, make sure that ENG/MASTER 1 and 2 control switches are set to OFF.
Subtask 26-12-00-865-065-A ** ON A/C NOT FOR ALL C. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | ENGINE/2/FIRE DET/LOOP B | 8WD2 | A07 |
| 49VU | ENGINE/1/FIRE DET/LOOP A | 7WD1 | A06 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/A | 1WE1 | Q43 |
| 121VU | ENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/A | 1WE2 | Q41 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/ENG2/FIRE DET/LOOP A | 7WD2 | Q39 |
| 121VU | ENGINE/ENG1/FIRE DET/LOOP B | 8WD1 | Q38 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/B | 2WE1 | Q44 |
| 121VU | ENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/B | 2WE2 | Q42 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/B | 2WE1 | Q44 |
| 121VU | ENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/B | 2WE2 | Q42 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/B | 2WE1 | Q43 |
| 121VU | ENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/A | 1WE1 | Q42 |
| 121VU | ENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/B | 2WE2 | Q41 |
| 121VU | ENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/A | 1WE2 | Q40 |
Subtask 26-12-00-710-054-A ** ON A/C NOT FOR ALL
A. Operational Test of the Engine Fire and Overheat Detection with the CFDS
(1) On the Multipurpose Control and Display Unit (MCDU), get the SYSTEM REPORT/TEST/FIRE PROT page (Ref. AMM TASK 31-32-00-860-005).
(2) Do this test:
5. Close-up(1) On the Multipurpose Control and Display Unit (MCDU), get the SYSTEM REPORT/TEST/FIRE PROT page (Ref. AMM TASK 31-32-00-860-005).
(2) Do this test:
| ACTION | RESULT |
|---|---|
| 1.On the MCDU: | On the MCDU: |
|
|
| On the FDU 1(2) page:
NOTE: You can ignore all the other indications. |
Subtask 26-12-00-869-055-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) On the MCDU, push the line select key adjacent to the RETURN indication until the CFDS menu page comes into view.
Subtask 26-12-00-862-055-A ** ON A/C NOT FOR ALL (1) On the MCDU, push the line select key adjacent to the RETURN indication until the CFDS menu page comes into view.