Removal of the Cargo-Compartment Smoke Detectors
TASK 26-16-15-000-001-A
Removal of the Cargo-Compartment Smoke Detectors
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 26-16-15-861-051-A
Subtask 26-16-15-020-050-A ** ON A/C NOT FOR ALL
(2) Release the quick release fasteners (1).
(3) Remove the grid (2).
(4) Disconnect the electrical connector (3) from the smoke detector (6).
(5) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(6) Remove the screws (4) and the washers (5).
(7) Remove the smoke detector (6).
Subtask 26-16-15-020-050-B ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 04:07:57 UTC
Removal of the Cargo-Compartment Smoke Detectors
ZONE: 130
ZONE: 150
ZONE: 160
FIN: 1WH
FIN: 10WH ** ON A/C NOT FOR ALL
FIN: 2WH
FIN: 3WH
FIN: 4WH
FIN: 5WH
FIN: 6WH
FIN: 7WH ** ON A/C NOT FOR ALL
FIN: 8WH ** ON A/C NOT FOR ALL
FIN: 9WH ** ON A/C NOT FOR ALL
1. Reason for the JobZONE: 150
ZONE: 160
FIN: 1WH
FIN: 10WH ** ON A/C NOT FOR ALL
FIN: 2WH
FIN: 3WH
FIN: 4WH
FIN: 5WH
FIN: 6WH
FIN: 7WH ** ON A/C NOT FOR ALL
FIN: 8WH ** ON A/C NOT FOR ALL
FIN: 9WH ** ON A/C NOT FOR ALL
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| FOR [1WH] (DET-SMOKE, CARGO COMPT) | ||
| FOR [10WH] (DET-SMOKE, CARGO COMPT) | ||
| FOR [2WH] (DET-SMOKE, CARGO COMPT) | ||
| FOR [3WH] (DET-SMOKE, CARGO COMPT) | ||
| FOR [4WH] (DET-SMOKE, CARGO COMPT) | ||
| FOR [7WH] (DET-SMOKE, CARGO COMPT) | ||
| FOR [8WH] (DET-SMOKE, CARGO COMPT) | ||
| FOR [9WH] (DET-SMOKE, CARGO COMPT) | ||
| No specific | AR | CAP - BLANKING |
| FOR [5WH] (DET-SMOKE, CARGO COMPT) | ||
| FOR [6WH] (DET-SMOKE, CARGO COMPT) | ||
| No specific | AR | CAP - BLANKING |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 130 | FWD CARGO COMPT AFT BULKHEAD OF AVNCS COMPT TO FWD PRESSURE BULKHEAD OF WING CENTER BOX |
| 150 | AFT CARGO COMPARTMENT FWD PRESS BULKHEAD TO AFT BULKHEAD OF AFT CARGO COMPARTMENT |
| 160 | BULK CARGO COMPARTMENT AFT BULKHEAD OF AFT CARGO COMPARTMENT TO AFT BULKHEAD OF BULK CARGO COMPARTMENT |
| 251AF, 825, 826 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 53-42-12-000-001-A | Removal of the Cabin Floor Panels from FR47 thru FR64 |
Subtask 26-16-15-861-051-A
A. Aircraft Maintenance Configuration
(1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 26-16-15-010-051-B ** ON A/C NOT FOR ALL (1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
B. Get Access
(1) Remove the cabin floor panel 251AF to get access to the smoke detectors 5WH and 6WH (Ref. AMM TASK 53-42-12-000-001).
(2) Put a WARNING NOTICE(S) in position to tell persons to be careful about the opened floor panel.
(3) Open the forward cargo-compartment door 825 and the aft cargo-compartment door 826 (Ref. AMM TASK 52-30-00-860-001).
(4) In the forward cargo compartment, set the CARGO COMPT LIGHT switch 6LU to the ON position.
(5) In the aft cargo compartment, set the CARGO COMPT LIGHT switch 8LU to the ON position.
Subtask 26-16-15-865-050-A (1) Remove the cabin floor panel 251AF to get access to the smoke detectors 5WH and 6WH (Ref. AMM TASK 53-42-12-000-001).
(2) Put a WARNING NOTICE(S) in position to tell persons to be careful about the opened floor panel.
(3) Open the forward cargo-compartment door 825 and the aft cargo-compartment door 826 (Ref. AMM TASK 52-30-00-860-001).
(4) In the forward cargo compartment, set the CARGO COMPT LIGHT switch 6LU to the ON position.
(5) In the aft cargo compartment, set the CARGO COMPT LIGHT switch 8LU to the ON position.
C. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/SDCU/CHAN1 | 11WQ | C06 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/CIDS/SDF/DIR2 ESS | 18WH | C06 |
| 49VU | AIR COND/CIDS/SDF/DIR1 ESS | 15WH | C05 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/SDCU/CHAN2 | 12WQ | T18 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/CIDS/SDF/DIR NORM/2 | 14WH | T18 |
| 122VU | AIR COND/CIDS/SDF/DIR NORM/1 | 17WH | T17 |
Subtask 26-16-15-020-050-A ** ON A/C NOT FOR ALL
WARNING:
DO NOT OPEN OR REPAIR THE SMOKE DETECTOR.
IF THE SMOKE DETECTOR IS DAMAGED, PUT ON RUBBER GLOVES BEFORE YOU TOUCH IT.
THE SMOKE DETECTOR CONTAINS RADIOACTIVE MATERIAL WHICH IS DANGEROUS.
THUS ONLY WORKSHOPS APPROVED BY THE MANUFACTURER OF THE SMOKE DETECTOR ARE PERMITTED TO DO WORK ON IT.
WHEN YOU DISCARD IT, OBEY THE INSTRUCTIONS OF THE SMOKE DETECTOR MANUFACTURER. ALSO OBEY LOCAL REGULATIONS FOR RADIOACTIVE MATERIALS.
A. Removal of the Smoke Detector NOTE: The removal procedure is the same for all smoke detectors.
(1) Remove the ceiling smoke channels for access to the grid (2). (2) Release the quick release fasteners (1).
(3) Remove the grid (2).
(4) Disconnect the electrical connector (3) from the smoke detector (6).
(5) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(6) Remove the screws (4) and the washers (5).
(7) Remove the smoke detector (6).
A. Removal of the Smoke Detector
(2) Release the quick release fasteners (1).
(3) Remove the grid (2).
(4) Disconnect the electrical connector (3) from the smoke detector (6).
(5) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(6) Remove the screws (4) and the washers (5).
(7) Remove the smoke detector (6).
Subtask 26-16-15-020-050-D ** ON A/C NOT FOR ALL NOTE: The removal procedure is the same for all smoke detectors.
(1) Remove the ceiling smoke channels for access to the grid (2).(2) Release the quick release fasteners (1).
(3) Remove the grid (2).
(4) Disconnect the electrical connector (3) from the smoke detector (6).
(5) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(6) Remove the screws (4) and the washers (5).
(7) Remove the smoke detector (6).
A. Removal of the Smoke Detector
(a) Remove the ceiling smoke channels for access to the grid (2).
(b) Release the quick release fasteners (1).
(c) Remove the grid (2).
(d) Disconnect the electrical connector (3) from the smoke detector (6).
(e) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(f) Remove the screws (4) and the washers (5).
(g) Remove the smoke detector (6).
(2) FOR [5WH] (DET-SMOKE, CARGO COMPT), [6WH] (DET-SMOKE, CARGO COMPT)
(a) Remove the screws (10) and the washers (11).
(b) Move the plate (9) to the side and carefully lift it together with the smoke detector (17) to get access to the electrical connector (18).
(c) Disconnect the electrical connector (18) from the smoke detector (17).
(d) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(e) Remove the nuts (15), the washers (8), the screws (7) and the spacers (12,13).
(f) Remove the plate (9) and the angles (14) from the smoke detector (17).
NOTE: The removal procedure is not the same for all smoke detectors.
(1) FOR [1WH] (DET-SMOKE, CARGO COMPT), [2WH] (DET-SMOKE, CARGO COMPT), [3WH] (DET-SMOKE, CARGO COMPT), [4WH] (DET-SMOKE, CARGO COMPT), [7WH] (DET-SMOKE, CARGO COMPT), [8WH] (DET-SMOKE, CARGO COMPT), [9WH] (DET-SMOKE, CARGO COMPT), [10WH] (DET-SMOKE, CARGO COMPT)(a) Remove the ceiling smoke channels for access to the grid (2).
(b) Release the quick release fasteners (1).
(c) Remove the grid (2).
(d) Disconnect the electrical connector (3) from the smoke detector (6).
(e) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(f) Remove the screws (4) and the washers (5).
(g) Remove the smoke detector (6).
(2) FOR [5WH] (DET-SMOKE, CARGO COMPT), [6WH] (DET-SMOKE, CARGO COMPT)
(a) Remove the screws (10) and the washers (11).
(b) Move the plate (9) to the side and carefully lift it together with the smoke detector (17) to get access to the electrical connector (18).
(c) Disconnect the electrical connector (18) from the smoke detector (17).
(d) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(e) Remove the nuts (15), the washers (8), the screws (7) and the spacers (12,13).
(f) Remove the plate (9) and the angles (14) from the smoke detector (17).