W DOC AIRBUS | AMM A320F

Removal of the Net Stanchions in the Forward Cargo Compartment


TASK 25-54-17-000-001-A
Removal of the Net Stanchions in the Forward Cargo Compartment


ZONE: 130
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
No specific
1
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
130
FWD CARGO COMPT AFT BULKHEAD OF AVNCS COMPT TO FWD PRESSURE BULKHEAD OF WING CENTER BOX
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 52-30-00-480-001-A
Installation of the Safety Support Equipment
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
3. Job Set-up
Subtask 25-54-17-010-050-A ** ON A/C NOT FOR ALL
A. Get Access
   (1) Open the forward cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
   (2) Put the ACCESS PLATFORM 2M (6 FT) in position at the opening of the forward cargo-compartment door.
Subtask 25-54-17-010-050-B ** ON A/C NOT FOR ALL
A. Get Access
   (1) Open the forward cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
   (2) Install the safety lock on the actuator of the forward cargo-compartment door (Ref. AMM TASK 52-30-00-480-001).
   (3) Put the ACCESS PLATFORM 2M (6 FT) in position at the opening of the forward cargo-compartment door.
   (4) Put a WARNING NOTICE(S) in position on the control panel of the forward Cargo Loading-System (CLS) to tell persons not to use it.
Subtask 25-54-17-865-053-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2000VUSEMI AUTO CLS-FWD3MYE08
2000VUSEMI AUTO CLS-FWD2MYE06
4. Procedure
Subtask 25-54-17-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Net Stanchions
   (1) Disconnect the net fittings from the applicable net attachment fittings of the cargo-compartment floor and ceiling areas.
   (2) Remove the stanchion (2):
     (a) Turn the locking base (3) counterclockwise to unlock the stanchion from the tie-down point (4).
     (b) Push the stanchion (2) up to release the stanchion locking base (3) from the tie-down point (4).
     (c) Move the lower part of the stanchion (2) away from the tie-down point (4).
     (d) Move the stanchion (2) down to remove the stanchion plunger from the upper ceiling fitting (1).