W DOC AIRBUS | AMM A320F

Installation of the Reinforced End Stops for the ACT


TASK 25-52-53-400-002-A
Installation of the Reinforced End Stops for the ACT


WARNING: DO NOT GET THE FLUID ON YOUR SKIN OR IN YOUR EYES. IF YOU DO:
  • FLUSH IT AWAY WITH CLEAN WATER
  • GET MEDICAL AID.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION: USE ONLY THE SPECIFIED MATERIALS AND OBEY THE INSTRUCTIONS FROM THE MATERIAL MANUFACTURERS. OTHER MATERIALS CAN CAUSE DAMAGE TO THE SURFACE PROTECTION OF THE COMPONENTS AND THE RELATED AREA.
ZONE: 150
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
No specific
1
SCRAPER - PLASTIC
No specific
1
SCRAPER - WOODEN
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.06AAC1)
Polysulfide Sealant-General Purpose Interfay -
(Material No.06LCG9)
Non Hardening Jointing Putty-Medium Temp. Area - -
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.12ABB1)
Corrosion Preventive Compound-Water Displacing Hard Film -
(Material No.12ACC1)
Corrosion Preventive Compound-Heavy Duty Soft Film -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
150
AFT CARGO COMPARTMENT FWD PRESS BULKHEAD TO AFT BULKHEAD OF AFT CARGO COMPARTMENT
 D. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
4
COTTER PINS
AIPC 25-52-04-26-060
 E. Referenced Information
REFERENCE
DESIGNATION
TASK 51-75-13-916-002-A
Repair to a layer of Corrosion Preventive Compound
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
TASK 52-30-00-860-002-A
Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
F Reinforced End Stop for 2 ACT ** ON A/C NOT FOR ALL
F Reinforced End Stops for the ACT ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 25-52-53-860-051-B ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the forward or aft cargo-compartment door is opened (Ref. AMM TASK 52-30-00-860-001).
   (2) Make sure that the ACCESS PLATFORM 2M (6 FT) is in position at the opening of the forward or aft cargo-compartment door.
4. Procedure
Subtask 25-52-53-910-051-A ** ON A/C NOT FOR ALL
A. Preparation for Installation
   (1) Remove the unwanted sealant from the reinforced end stops and the roller tracks with Non Aqueous Cleaner-General - - (Material No.08BAA9) and a SCRAPER - WOODEN or SCRAPER - PLASTIC.
   (2) Clean the component interfaces and the adjacent area.
   (3) Do an inspection of the component interfaces and the adjacent area.
   (4) Apply Non Hardening Jointing Putty-Medium Temp. Area - - (Material No.06LCG9) to the thread and the shaft of the bolts.
   (5) Apply a layer of Polysulfide Sealant-General Purpose Interfay - (Material No.06AAC1) to the mating surface of the reinforced end stops.
Subtask 25-52-53-420-051-A ** ON A/C NOT FOR ALL
B. Installation of the Reinforced End Stops
   (1) Install the reinforced end stops (1) and the rollers (2) with the bolts (7), the washers (6) and the nuts (5).
   (2) Safety the nuts (5) with new AIPC 25-52-04-26-060 COTTER PINS (4).
   (3) Apply Corrosion Preventive Compound-Water Displacing Hard Film - (Material No.
12ABB1) to the fasteners and all other connection elements.
   (4) Apply Corrosion Preventive Compound-Heavy Duty Soft Film - (Material No.12ACC1) to the material applied to the fasteners and the connection elements (Ref. AMM TASK 51-75-13-916-002).
Subtask 25-52-53-420-051-M ** ON A/C NOT FOR ALL
B. Installation of the Reinforced End Stops
   (1) Put the plates (8) in their correct installation positions in the roller track (3).
   (2) Put the reinforced end stop (1) and the roller (2) in position in the roller track (3).
   (3) Install the bolts (7), the washers (6) and the nuts (5).
   (4) Apply Corrosion Preventive Compound-Water Displacing Hard Film - (Material No.12ABB1) to the fasteners and all other connection elements.
   (5) Safety the nuts (5) with the new cotter pins (4).
5. Close-up
Subtask 25-52-53-410-053-B ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the access platform(s).
   (3) Close the forward or aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-002).
[Rev.10 from 2021] 2026.04.01 06:23:23 UTC