Removal of the Galley Control Panel
TASK 25-35-34-000-001-A
Removal of the Galley Control Panel
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 25-35-34-861-050-A Subtask 25-35-34-865-053-A
Subtask 25-35-34-020-050-A
[Rev.10 from 2021]
2026.03.31 23:34:38 UTC
Removal of the Galley Control Panel
ZONE: 200
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 200 | UPPER HALF FUSELAGE |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
Subtask 25-35-34-861-050-A Subtask 25-35-34-865-053-A
B. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | ELEC/GALLEY/CNTOR | 7MC | S28 |
| 122VU | ELEC/GALY & CAB/CTL | 1XA | S26 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | AFT GALLEY/FEEDER A | 3MC | AF04 |
| ** ON A/C ALL | |||
| 123VU | FWD GALLEY/FEEDER F | 16MC | AC10 |
| 123VU | AFT GALLEY/FEEDER E | 14MC | AF09 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | AFT GALLEY/FEEDER B | 12MC | AD09 |
| 123VU | FWD GALLEY/FEEDER D | 2MC | AD04 |
| 123VU | FWD GALLEY/FEEDER C | 1MC | AE10 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | FWD GALLEY/FEEDER D | 2MC | AE02 |
Subtask 25-35-34-020-050-A
A. Removal of the Galley Control-Panel
(1) Remove the screws (1).
(2) Carefully pull the galley control-panel (2) out of the galley.
(3) Disconnect the electrical connectors (3).
(4) Remove the galley control-panel (2) from the galley.
(5) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(1) Remove the screws (1).
(2) Carefully pull the galley control-panel (2) out of the galley.
(3) Disconnect the electrical connectors (3).
(4) Remove the galley control-panel (2) from the galley.
(5) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
Galley Control Panel