W DOC AIRBUS | AMM A320F

Removal of the Air Chiller Unit - Galley 2


TASK 25-34-51-000-003-A
Removal of the Air Chiller Unit - Galley 2


ZONE: 220
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
220
FWD CAB UTILITY AREAS
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
3. Job Set-up
Subtask 25-34-51-861-054-A ** ON A/C NOT FOR ALL
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 25-34-51-941-052-A ** ON A/C NOT FOR ALL
B. Safety Precautions
   (1) On the overhead panel, on AIR COND panel 30VU:
     (a) Make sure that these pushbutton switches are released:
  • APU BLEED pushbutton switch (the ON legend is off)
  • All the ENG BLEED pushbutton switches (the OFF legends are on)
  • PACK 1 and PACK 2 pushbutton switches (the OFF legends are on).
     (b) Put the WARNING NOTICE(S) in position to tell persons not to operate these pushbutton switches.
   (2) On the HP and LP ground-air connectors:
     (a) Put the WARNING NOTICE(S) in position to tell persons not to connect the ground air supply.
Subtask 25-34-51-865-082-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
122VUELEC/GALLEY/CNTOR7MCS28
122VUELEC/GALY & CAB/CTL1XAS26
122VUAIR COND/LAV/GALLEY VENT CTL/EXTRACT FAN/CTL5HUU21
122VUAIR COND/LAV/GALLEY VENT CTL/EXTRACT FAN/SPLY6HUU19
123VUFWD GALLEY/FEEDER F16MCAC10
123VUFWD GALLEY/FEEDER D2MCAD04
Subtask 25-34-51-010-052-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) Remove the decorative material, if necessary.
4. Procedure
Subtask 25-34-51-020-053-A ** ON A/C NOT FOR ALL
WARNING: SUPPORT THE UNIT/ASSEMBLY. THE UNIT/ASSEMBLY IS HEAVY. IF YOU DO NOT SUPPORT IT, IT WILL FALL. THIS CAN CAUSE INJURY TO PERSONS, AND/OR DAMAGE TO EQUIPMENT.
A. Removal of the Air Chiller Unit - Galley 2
F Air Chiller - Galley 2 ** ON A/C NOT FOR ALL
   (1) Remove the screws (1) and the panel (2).
   (2) Remove the screws (6) and the shelf assembly (5).
   (3) Remove the screws (4) and the side panel (3).
   (4) Disconnect the electrical connectors (10) and (9).
   (5) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (6) Remove the screws (8).
   (7) Carefully remove the air chiller (7).
[Rev.9 from 2019] 2026.03.31 23:34:03 UTC