Removal of the Air Chiller Unit - Galley 2
TASK 25-34-51-000-003-A
Removal of the Air Chiller Unit - Galley 2
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 25-34-51-861-054-A ** ON A/C NOT FOR ALL Subtask 25-34-51-941-052-A ** ON A/C NOT FOR ALL
Subtask 25-34-51-020-053-A ** ON A/C NOT FOR ALL
(1) Remove the screws (1) and the panel (2).
(2) Remove the screws (6) and the shelf assembly (5).
(3) Remove the screws (4) and the side panel (3).
(4) Disconnect the electrical connectors (10) and (9).
(5) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(6) Remove the screws (8).
(7) Carefully remove the air chiller (7).
[Rev.9 from 2019]
2026.03.31 23:34:03 UTC
Removal of the Air Chiller Unit - Galley 2
ZONE: 220
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 220 | FWD CAB UTILITY AREAS |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
Subtask 25-34-51-861-054-A ** ON A/C NOT FOR ALL Subtask 25-34-51-941-052-A ** ON A/C NOT FOR ALL
B. Safety Precautions
(1) On the overhead panel, on AIR COND panel 30VU:
(a) Make sure that these pushbutton switches are released:
(2) On the HP and LP ground-air connectors:
(a) Put the WARNING NOTICE(S) in position to tell persons not to connect the ground air supply.
Subtask 25-34-51-865-082-A ** ON A/C NOT FOR ALL (1) On the overhead panel, on AIR COND panel 30VU:
(a) Make sure that these pushbutton switches are released:
- APU BLEED pushbutton switch (the ON legend is off)
- All the ENG BLEED pushbutton switches (the OFF legends are on)
- PACK 1 and PACK 2 pushbutton switches (the OFF legends are on).
(2) On the HP and LP ground-air connectors:
(a) Put the WARNING NOTICE(S) in position to tell persons not to connect the ground air supply.
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 25-34-51-010-052-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 122VU | ELEC/GALLEY/CNTOR | 7MC | S28 |
| 122VU | ELEC/GALY & CAB/CTL | 1XA | S26 |
| 122VU | AIR COND/LAV/GALLEY VENT CTL/EXTRACT FAN/CTL | 5HU | U21 |
| 122VU | AIR COND/LAV/GALLEY VENT CTL/EXTRACT FAN/SPLY | 6HU | U19 |
| 123VU | FWD GALLEY/FEEDER F | 16MC | AC10 |
| 123VU | FWD GALLEY/FEEDER D | 2MC | AD04 |
D. Get Access
(1) Remove the decorative material, if necessary.
4. Procedure(1) Remove the decorative material, if necessary.
Subtask 25-34-51-020-053-A ** ON A/C NOT FOR ALL
WARNING:
SUPPORT THE UNIT/ASSEMBLY. THE UNIT/ASSEMBLY IS HEAVY. IF YOU DO NOT SUPPORT IT, IT WILL FALL. THIS CAN CAUSE INJURY TO PERSONS, AND/OR DAMAGE TO EQUIPMENT.
A. Removal of the Air Chiller Unit - Galley 2 (1) Remove the screws (1) and the panel (2).
(2) Remove the screws (6) and the shelf assembly (5).
(3) Remove the screws (4) and the side panel (3).
(4) Disconnect the electrical connectors (10) and (9).
(5) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(6) Remove the screws (8).
(7) Carefully remove the air chiller (7).