Removal of the Advanced Power Converter(s)
TASK 25-21-36-000-802-A
Removal of the Advanced Power Converter(s)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 25-21-36-861-051-A ** ON A/C NOT FOR ALL Subtask 25-21-36-865-055-A ** ON A/C NOT FOR ALL
Subtask 25-21-36-020-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:30:21 UTC
Removal of the Advanced Power Converter(s)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
Subtask 25-21-36-861-051-A ** ON A/C NOT FOR ALL Subtask 25-21-36-865-055-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | INSEAT POWER-MCU 2 | 59HP | B08 |
| 2000VU | INSEAT POWER-MCU 1 | 58HP | B05 |
Subtask 25-21-36-020-051-A ** ON A/C NOT FOR ALL
A. Removal of the advanced power converter
(1) Release the fasteners (2) and remove the covers (1).
(2) Disconnect the electrical connectors:
(b) Disconnect the electrical connectors (4) and (7) from advanced power converter (6).
(c) Put a CAP - BLANKING on each disconnected electrical connector.
(d) Remove the nuts (8), the washers (9) and disconnect the bonding straps (10).
(e) Hold the advanced power converter (6) tightly, release the fasteners (3) and remove the advanced power converter(6).
(1) Release the fasteners (2) and remove the covers (1).
(2) Disconnect the electrical connectors:
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTOR(S) IS(ARE) DISCONNECTED BEFORE YOU DISCONNECT THE BONDING STRAP(S).
(a) Release the spring latches (5). (b) Disconnect the electrical connectors (4) and (7) from advanced power converter (6).
(c) Put a CAP - BLANKING on each disconnected electrical connector.
(d) Remove the nuts (8), the washers (9) and disconnect the bonding straps (10).
(e) Hold the advanced power converter (6) tightly, release the fasteners (3) and remove the advanced power converter(6).
Advanced Power Converter