Removal of the Power Outlet Unit
TASK 25-18-11-000-801-A
Removal of the Power Outlet Unit
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 25-18-11-861-050-A ** ON A/C NOT FOR ALL Subtask 25-18-11-865-050-A ** ON A/C NOT FOR ALL
Subtask 25-18-11-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:29:34 UTC
Removal of the Power Outlet Unit
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
Subtask 25-18-11-861-050-A ** ON A/C NOT FOR ALL Subtask 25-18-11-865-050-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | PILOTS OUTLETS/STAT INV | 1NA | K25 |
| 121VU | PILOTS OUTLETS/115V 60HZ | 2NA | K23 |
Subtask 25-18-11-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Power Outlet Unit
(2) Disconnect the electrical connectors from the power outlet unit (2).
(3) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(4) Remove the screws (3).
(5) Remove the power outlet unit (2) from the VU panel (1).
CAUTION:
WHEN YOU REMOVE THE SCREWS AND WASHERS OF THE POWER OUTLET UNIT, BE CAREFUL NOT TO CAUSE DAMAGE TO THE ELECTRICAL CONNECTORS.
(1) Remove the screws (4) and the washers (5). (2) Disconnect the electrical connectors from the power outlet unit (2).
(3) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(4) Remove the screws (3).
(5) Remove the power outlet unit (2) from the VU panel (1).
Power Outlet Unit