General Visual Inspection of the EWIS Installed in the Pylon-to-Wing Leading Edge (EWIS)
TASK 24-92-00-210-820-A
General Visual Inspection of the EWIS Installed in the Pylon-to-Wing Leading Edge (EWIS)
1. Reason for the Job
Refer to the MPD TASK: 200471-02
GENERAL VISUAL INSPECTION OF EWIS INSTALLED IN THE PYLON TO WING LEADING EDGE (EWIS)
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 24-92-00-941-080-A
Subtask 24-92-00-210-125-A
Subtask 24-92-00-410-206-A
[Rev.10 from 2021]
2026.03.31 23:26:52 UTC
General Visual Inspection of the EWIS Installed in the Pylon-to-Wing Leading Edge (EWIS)
1. Reason for the Job
Refer to the MPD TASK: 200471-02
GENERAL VISUAL INSPECTION OF EWIS INSTALLED IN THE PYLON TO WING LEADING EDGE (EWIS)
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| No specific | 1 | FLASHLIGHT |
| No specific | 1 | MIRROR - INSPECTION, FLEXIBLE |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 471 | PYLON LEADING EDGE |
| 472 | PYLON LEADING EDGE |
| 481 | PYLON LEADING EDGE |
| 482 | PYLON LEADING EDGE |
| 471AL, 471BL, 471CL, 472AR, 472BR, 481AL, 481BL, 482AR, 482BR, 482CR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 54-53-11-000-806-A | Removal of the Pylon-to-Wing Access Panels and Doors |
| TASK 54-53-11-400-806-A | Installation of the Pylon-to-Wing Access Panels and Doors |
| ESPM 2052110 | |
Subtask 24-92-00-941-080-A
A. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate the ENG/MODE selector switch and the ENG/MASTER 1(2) control switch.
(2) On the ENG section of maintenance panel 50VU:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 24-92-00-010-199-A (1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate the ENG/MODE selector switch and the ENG/MASTER 1(2) control switch.
(2) On the ENG section of maintenance panel 50VU:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
B. Get Access
(1) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position:
(a) For the left pylon, in zone 470
(b) For the right pylon, in zone 480.
(2) Remove the pylon-to-wing access panels and doors (Ref. AMM TASK 54-53-11-000-806):
(a) For the left pylon, 471AL 471BL 471CL 472AR 472BR
(b) For the right pylon, 481AL 481BL 482AR 482BR 482CR.
4. Procedure(1) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position:
(a) For the left pylon, in zone 470
(b) For the right pylon, in zone 480.
(2) Remove the pylon-to-wing access panels and doors (Ref. AMM TASK 54-53-11-000-806):
(a) For the left pylon, 471AL 471BL 471CL 472AR 472BR
(b) For the right pylon, 481AL 481BL 482AR 482BR 482CR.
Subtask 24-92-00-210-125-A
A. General Visual Inspection of the EWIS Installed in the Pylon-to-Wing Leading Edge
(1) Do a visual inspection of the wiring to make sure that there is no signs of ageing, alteration, overheating, scaling and deformation ESPM 2052110:
(a) On AC/DC feeder routes 1G and 2G
(b) On engine control routes 1S and 2S
(c) On routes 1M and 2M.
1 Use a FLASHLIGHT or a MIRROR - INSPECTION, FLEXIBLE if necessary.
(2) Make sure that there is no dust, fuel, oil or hydraulic contamination.
5. Close-up(1) Do a visual inspection of the wiring to make sure that there is no signs of ageing, alteration, overheating, scaling and deformation ESPM 2052110:
(a) On AC/DC feeder routes 1G and 2G
(b) On engine control routes 1S and 2S
(c) On routes 1M and 2M.
1 Use a FLASHLIGHT or a MIRROR - INSPECTION, FLEXIBLE if necessary.
(2) Make sure that there is no dust, fuel, oil or hydraulic contamination.
Subtask 24-92-00-410-206-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the pylon-to-wing access panels and doors (Ref. AMM TASK 54-53-11-400-806):
(a) For the left pylon, 471AL 471BL 471CL 472AR 472BR
(b) For the right pylon, 481AL 481BL 482AR 482BR 482CR.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the pylon-to-wing access panels and doors (Ref. AMM TASK 54-53-11-400-806):
(a) For the left pylon, 471AL 471BL 471CL 472AR 472BR
(b) For the right pylon, 481AL 481BL 482AR 482BR 482CR.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
Access Panels of the Left Pylon