Removal of the Stand-Alone Passenger Interface and Supply Adapter (StA-PISA)
TASK 23-73-41-000-802-A
Removal of the Stand-Alone Passenger Interface and Supply Adapter (StA-PISA)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 23-73-41-010-050-A ** ON A/C NOT FOR ALL
Subtask 23-73-41-020-054-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:18:33 UTC
Removal of the Stand-Alone Passenger Interface and Supply Adapter (StA-PISA)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 1 | STEPLADDER 0.5 M (1.6 FT) |
| No specific | 1 | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 121AL |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 33-27-00-00 | LIGHT - WORK, CABIN ATTENDANT - DESCRIPTION AND OPERATION |
Subtask 23-73-41-010-050-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Put the ACCESS PLATFORM 1M(3 FT) in position at the access door 121AL.
(2) Open the access door 121AL.
(3) Put the STEPLADDER 0.5 M (1.6 FT) in position below the related StA-PISA.
Subtask 23-73-41-941-051-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 1M(3 FT) in position at the access door 121AL.
(2) Open the access door 121AL.
(3) Put the STEPLADDER 0.5 M (1.6 FT) in position below the related StA-PISA.
NOTE: For location of StA-PISA refer to (Ref. AMM D/O 33-27-00-00).
B. Safety Precautions
(1) Make sure that the external power connector is not connected to the aircraft EXT PWR receptacle.
(2) Put WARNING NOTICE(S) in position on access door 121AL to tell persons not to connect the external power connector to the aircraft EXT PWR receptacle.
(3) In the cockpit, on ELEC panel 35VU, make sure that these pushbutton switches are released:
Subtask 23-73-41-865-064-A ** ON A/C NOT FOR ALL (1) Make sure that the external power connector is not connected to the aircraft EXT PWR receptacle.
(2) Put WARNING NOTICE(S) in position on access door 121AL to tell persons not to connect the external power connector to the aircraft EXT PWR receptacle.
(3) In the cockpit, on ELEC panel 35VU, make sure that these pushbutton switches are released:
- BAT 1, BAT 2
- APU GEN
- GEN 1, GEN 2
- EXT PWR.
- 21VU (EMER ELEC PWR section)
- 25VU (APU section)
- 35VU (ELEC).
C. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM/CIDS/DIR ESS/2 | 157RH | G02 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM/CIDS/DIR ESS/1 | 150RH | G01 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/CIDS/SDF/DIR2 ESS | 18WH | C06 |
| 49VU | AIR COND/CIDS/SDF/DIR1 ESS | 15WH | C05 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM DIR ESS/2 | 157RH | G02 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM NAV/CIDS/DIR2 ESS | 157RH | G02 |
| 49VU | COM NAV/CIDS/DIR1 ESS | 150RH | G01 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/DEU A NORM/R AFT | 168RH | M12 |
| 121VU | COM NAV/CIDS/DEU A NORM/L AFT | 167RH | M11 |
| 121VU | COM NAV/CIDS/DEU A NORM/R FWD | 164RH | M10 |
| 121VU | COM NAV/CIDS/DEU A NORM/L FWD | 163RH | M09 |
| 121VU | COM NAV/CIDS/DIR NORM/2 | 156RH | M06 |
| 121VU | COM NAV/CIDS/DIR NORM/1 | 151RH | M05 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/DEU A NORM/R FWD | 164RH | M11 |
| 121VU | COM NAV/CIDS/DEU A NORM/L FWD | 163RH | M10 |
| 121VU | COM NAV/CIDS/DIR NORM/2 | 156RH | M07 |
| 121VU | COM NAV/CIDS/DIR NORM/1 | 151RH | M06 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/DIR2 NORM | 156RH | M06 |
| 121VU | COM NAV/CIDS/DIR1 NORM | 151RH | M05 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/CIDS/SDF/DIR NORM/2 | 14WH | T18 |
| 122VU | AIR COND/CIDS/SDF/DIR NORM/1 | 17WH | T17 |
| 122VU | ELEC/EXT PWR/LT CLT/NOT IN/USE | 6XG | X30 |
| 2000VU | LIGHT-ATTND-WORK | 1LZ | J03 |
Subtask 23-73-41-020-054-A ** ON A/C NOT FOR ALL
A. Removal of the Stand Alone Passenger Interface and Supply Adapter (StA-PISA)
(1) Do the subsequent steps to open the related circuit breaker panel:
(b) Release the detent hook and lower one side of the related circuit breaker panel until it hangs in the vertical position.
(2) Do the subsequent steps to remove the StA-PISA:
(a) Identify the electrical connectors (6), (7) and (8) and make a note of their position before you disconnect them.
(b) Release the related spring latches (4),(5) and (9) and carefully disconnect three electrical connectors (6), (7) and (8) from the StA-PISA (1).
(c) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(d) Make a note of the position of the StA-PISA (1) before you remove it.
(e) Make a note of the position of the cable clips which keep the related cable loom in position.
(f) Hold the StA-PISA (1) and remove the screws (2), the washers (3) and the related cable clips.
(g) Remove the StA-PISA (1).
(h) If you do not install a new StA-PISA directly after the removal, make sure you close the related circuit breaker panel before you leave the A/C.
Subtask 23-73-41-020-054-B ** ON A/C NOT FOR ALL (1) Do the subsequent steps to open the related circuit breaker panel:
WARNING:
BE VERY CAREFUL WHEN YOU DO WORK ON CIRCUIT BREAKER PANELS. THERE IS A HIGH VOLTAGE BEHIND THESE PANELS.
(a) Release the quick-release fasteners and lower the related circuit breaker panel carefully. The circuit breaker panel is held to the adjacent center ceiling panel by a detent hook. (b) Release the detent hook and lower one side of the related circuit breaker panel until it hangs in the vertical position.
(2) Do the subsequent steps to remove the StA-PISA:
(a) Identify the electrical connectors (6), (7) and (8) and make a note of their position before you disconnect them.
(b) Release the related spring latches (4),(5) and (9) and carefully disconnect three electrical connectors (6), (7) and (8) from the StA-PISA (1).
(c) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(d) Make a note of the position of the StA-PISA (1) before you remove it.
(e) Make a note of the position of the cable clips which keep the related cable loom in position.
(f) Hold the StA-PISA (1) and remove the screws (2), the washers (3) and the related cable clips.
(g) Remove the StA-PISA (1).
(h) If you do not install a new StA-PISA directly after the removal, make sure you close the related circuit breaker panel before you leave the A/C.
A. Removal of the Stand Alone Passenger Interface and Supply Adapter (StA-PISA)
(1) Do the subsequent steps to open the related circuit breaker panel:
(b) Release the detent hook and lower one side of the related circuit breaker panel until it hangs in the vertical position.
(2) Do the subsequent steps to remove the StA-PISA:
(a) Identify the electrical connectors (6) and (7) and make a note of their position before you disconnect them.
(b) Release the related spring latches (4) and (5) and carefully disconnect two electrical connectors (6) and (7) from the StA-PISA (1).
(c) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(d) Make a note of the position of the StA-PISA (1) before you remove it.
(e) Make a note of the position of the cable clips which keep the related cable loom in position.
(f) Hold the StA-PISA (1) and remove the screws (2), the washers (3) and the related cable clips.
(g) Remove the StA-PISA (1).
(h) If you do not install a new StA-PISA directly after the removal, make sure you close the related circuit breaker panel before you leave the A/C.
(1) Do the subsequent steps to open the related circuit breaker panel:
WARNING:
BE VERY CAREFUL WHEN YOU DO WORK ON CIRCUIT BREAKER PANELS. THERE IS A HIGH VOLTAGE BEHIND THESE PANELS.
(a) Release the quick-release fasteners and lower the related circuit breaker panel carefully. The circuit breaker panel is held to the adjacent center ceiling panel by a detent hook. (b) Release the detent hook and lower one side of the related circuit breaker panel until it hangs in the vertical position.
(2) Do the subsequent steps to remove the StA-PISA:
(a) Identify the electrical connectors (6) and (7) and make a note of their position before you disconnect them.
(b) Release the related spring latches (4) and (5) and carefully disconnect two electrical connectors (6) and (7) from the StA-PISA (1).
(c) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(d) Make a note of the position of the StA-PISA (1) before you remove it.
(e) Make a note of the position of the cable clips which keep the related cable loom in position.
(f) Hold the StA-PISA (1) and remove the screws (2), the washers (3) and the related cable clips.
(g) Remove the StA-PISA (1).
(h) If you do not install a new StA-PISA directly after the removal, make sure you close the related circuit breaker panel before you leave the A/C.