W DOC AIRBUS | AMM A320F

Check of the Aircraft Electrical Grounding


TASK 20-28-00-720-012-A
Check of the Aircraft Electrical Grounding


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
MEGOHMETER MULTIRANGE
No specific
1
PLATE 1.2 M (4 FT) - STEEL, SQUARED
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 20-28-00-869-002-A
Table of the Maximum Permitted Resistance-Values
3. Job Set-up
Subtask 20-28-00-420-091-A
A. Equipment
   (1) MEGOHMETER MULTIRANGE with the applicable leads and prods:
  • Set the megohmmeter range to a value that is higher than the maximum permitted value of the assembly that you will measure. Refer to (Ref. AMM TASK 20-28-00-869-002).
  • Set the tension to 500 VDC.
   (2) PLATE 1.2 M (4 FT) - STEEL, SQUARED.
4. Procedure
Subtask 20-28-00-210-064-A
A. Measurement of the Resistance Value
   (1) Put the PLATE 1.2 M (4 FT) - STEEL, SQUARED between the tires of the nose landing gear and the ground.
   (2) Measure the resistance between the plate and the nose gear leg with a MEGOHMETER MULTIRANGE.
NOTE: This procedure is easier if you make the tire/plate contact moist.
   (3) Make sure that the measured values are not higher than the maximum permitted resistance-values (Ref. AMM TASK 20-28-00-869-002).
   (4) Remove the test equipment.
5. Close-up
Subtask 20-28-00-942-101-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
[Rev.10 from 2021] 2026.03.31 23:00:18 UTC